Re: Tek/HP/Etc chat server
That is a very good point! Unless the "elders" find participating enticing, it may wind up being just another forum, albeit with bells and whistles. (I mean "elder" in the respectful sense of "those
By
pdxareaid
·
#189207
·
|
Re: tek 2213 vs 2215
Hi! A good resource for this kind of question is TekWiki. You can download instruction & servicemanuals for your scopes here: https://w140.com/tekwiki/wiki/2213 https://w140.com/tekwiki/wiki/2215
By
Holger L¨¹bben
·
#189206
·
|
Re: Tek 465B graticule lights
Thanks Michael! I¡¯ll be looking into those today, much appreciated!
By
jgiv510070@...
·
#189205
·
|
Re: Tektronix 2445 Rebuild and Fan Issue
I have also 3D printed with a resin printer an entire replacement collet assembly. Reach out to me if you need some. [email protected]> wrote:
By
Li Gangyi
·
#189204
·
|
Re: tek 2213 vs 2215
nswer that question. But if you can get a cheap and functional 2215, why would you go into the trouble of putting a good 2213 board in your faulty 2215, and ruining your 2213 in the process?
By
Stephen
·
#189203
·
|
Tektronix TDS 2012B
Hi i have the chance of a Tektronix TDS 2012B that just shows a blank display,is that common?,also is it gonna be fixable?,tia
By
quadzillatech@...
·
#189201
·
|
Re: tek 2213 vs 2215
can no one shed light on this?
By
quadzillatech@...
·
#189200
·
|
Re: RG501 Ramp Generator running at double speed?
"This one goes to eleven!"? LOL!? ?Jim Ford?Sent from my T-Mobile 4G LTE Device
By
Jim Ford
·
#189199
·
|
Re: RG501 Ramp Generator running at double speed?
The dial is just a potentiometer, no steps on this one. The manual says it is only calibrated on the '1' position, and all other positions are uncalibrated, it does go up to 11 though, but I guess
By
Jared Cabot
·
#189198
·
|
Re: RG501 Ramp Generator running at double speed?
Is it simply the knob being off by one position on the shaft (or are is it 1-2-5?)?
By
David C. Partridge
·
#189197
·
|
Re: Tek/HP/Etc chat server
I get a blank screen on my iPad, and a login screen on my PC for somewhere where I don't have a login, but as regards the whole project I'll be staying here thanks. I don't need a precious source of
By
EJP
·
#189196
·
|
Re: RG501 Ramp Generator running at double speed?
I have it set to internal trigger but the output discrepancy is the same when triggered from my TG501A Time Mark Generator. If I set the Time Mark Generator to 0.1us and the Ramp Generator to 1us, I
By
Jared Cabot
·
#189195
·
|
Re: Tektronix 2445 Rebuild and Fan Issue
I'm not sure how damaged your collet is, but this is how I fixed mine: https://youtu.be/Rks_AyfJNq4?t=874 Hope that helps a bit.
By
Jared Cabot
·
#189194
·
|
Re: RG501 Ramp Generator running at double speed?
This might be obvious, but is the trigger signal at the right rate? I'm assuming that the voltages at each chip are correct... Don't have one, but that's what I'd think about, other than if the thing
By
Harvey White
·
#189193
·
|
RG501 Ramp Generator running at double speed?
Hi, I am currently repairing an RG501 Ramp Generator and have found it seems to be running at double speed, that is, when I set it to 1ms, it produces ramps of 500us width, this double speed is true
By
Jared Cabot
·
#189192
·
|
Looking for Clarostat Concentric Pot
It's a long shot but I'm looking for one of the Clarostat pots that has the concentric shaft so that either another piggy-backed pot or switch is actuated using the 1/6" diameter shaft. The SLOPE
By
n4buq
·
#189191
·
|
tek 2213 vs 2215
let me start by saying i have a 2215 with a faulty mainboard,but have the chance of a 2215 cheap,will the 2213 mainboard fit the 2215?,also what are the differences with them as both 60mhz tia.
By
quadzillatech@...
·
#189190
·
|
Re: Tektronix 2445 Rebuild and Fan Issue
[email protected]> wrote: 2. I've seen the post on the fan rebuild and I know my limits - not going I converted my 2465 to a temperature-controlled PC fan. I hated the whining of the fan enough that
By
Sigur?ur ?sgeirsson
·
#189189
·
|
Re: Tek/HP/Etc chat server
Try again, let me know if you're still having trouble.
By
cheater cheater
·
#189188
·
|
Re: Tek 465B graticule lights
Refer to Schematic #12 POWER SUPPLY. The entire circuit is laid out there and this will help guide you. NOTE: I am referencing Manual # 070-2757-00. Other manuals may be slightly different Confirm no
By
Michael W. Lynch
·