Free for shipping: Tekelec V.35 interface module
Got it from the Telogy auctions years ago and have no use for it.? No part number, but comes with v.35 cable and internal ribbon cable.? Can provide photos to interested parties (please contact me
By
Dave Seiter
·
#155358
·
|
Re: WTB 012-0648-00 6 pin LEMO M-M 30" cable for Tracking Generator
Hi https://www.ebay.co.uk/itm/LEMO-S-SERIES-6-WAY-PLUG-FFA-1S-306-fd6j28-/121740345972 https://www.mouser.es/datasheet/2/232/unipole_multipole-973098.pdf Is 1s, 12mm, not 2s, 14,8mm Regards Miguel
By
Miguel Work
·
#155357
·
|
Re: WTB 012-0648-00 6 pin LEMO M-M 30" cable for Tracking Generator
https://www.ebay.es/itm/LEMO-Grose-2S-Kabel-Stecker-6-polig-FFA-2S-306/370994224213?hash=item5660fa9c55:g:WLkAAOxycmBS4-MI is this? -----Mensaje original----- De: [email protected]
By
Miguel Work
·
#155356
·
|
Re: Test input for an SD-32 sampling head
LOL With *great* difficulty. That's a large part of the appeal of the project. It's not very expensive and if I succeed serious bragging rights. It would be great fun to take to a Keysight trade show
By
Reginald Beardsley
·
#155355
·
|
Re: 2247A PSU Troubleshooting
I have a Danica SV03 which is an isolated 3A variable source with V & A meters, but when you look inside it is simply a standard variable transformer with a separate isolation transformer so wouldn't
By
Adrian Nicol
·
#155354
·
|
Re: 2247A PSU Troubleshooting
There are variacs with an isolation transformer built in. But very rare. I own one made by Philips a dutch company.
By
Fred Schumacher
·
#155353
·
|
Re: 2247A PSU Troubleshooting
All variacs that I know of are auto-tranformers, so no isolation. David
By
David C. Partridge
·
#155352
·
|
Re: 2247A PSU Troubleshooting
Hi Brian, I found your post very informative but wanted to keep things as simple and clear as possible for the OP. I had recommended a Variac and he wasn't sure what to do. In his case he can either
By
Raymond Domp Frank
·
#155351
·
|
Re: 2247A PSU Troubleshooting
Variacs are tapped autotransformers. No isolation. You can get an assembly that combines a variac with an isolation transformer. Some companies make a device specifically for checking leakage and
By
Harvey White
·
#155350
·
|
Re: 2247A PSU Troubleshooting
In general, no. A Variac is just a primary with an adjustable tap. Variacs with isolation exist, having their adjustable tap on a secondary winding. Raymond
By
Raymond Domp Frank
·
#155349
·
|
Re: 577 Curve tracer ringing CRT and noisy step generator
/g/TekScopes/album?id=86536&p=Name,,,20,1,0,0 Updates to the photo gallery, probing the base of the 177 test fixtures reveals small parasitic spikes, I believe this is what is causing
By
DW
·
#155348
·
|
Re: 2247A PSU Troubleshooting
Interesting information Brian. I have often wondered if a Variac would provide isolation also. I have never checked mine I probably should. Regards John
By
John Williams
·
#155347
·
|
Re: 2247A PSU Troubleshooting
I was only answering to the comment about isolation transformers. If any user gets one then I hope they can check them out to be sure that they are safe instead of expecting it to work & getting
By
Brian Symons
·
#155346
·
|
Re: Test input for an SD-32 sampling head
And if you do get a 2ps rise pulse generator how do you check that that is up to its spec? Roger
By
Roger Evans
·
#155345
·
|
Re: Tektronix 015-0580-00 Pocket Signal Generator
Thank you for the additional information. I was curious if it would be of any interesting use when I came across it by chance on ebay. I do not own any TDS series scope and upon better understanding
By
Alex
·
#155344
·
|
Re: 2247A PSU Troubleshooting
Brian, Let's not confuse the OP. He has a 'scope with a HV (mains switching power supply) part that is galvanically connected to the mains and a LV part that is under normal conditions separated from
By
Raymond Domp Frank
·
#155343
·
|
Re: Test input for an SD-32 sampling head
With difficulty. I believe there's a method involving three sampling heads looking at each other's kickout pulses and some maths which can be used to evaluate their performance. The SD-24's pulse
By
cmjones01
·
#155342
·
|
Re: Not to be missed by 7854 fans...
John, Great find! Thanks for sharing. I¡¯m looking forward to seeing this! https://youtu.be/3Co8Z8BQgWc A hoard of never-developed film from the Apollo 11 mission was unearthed, some of it in 70mm.
By
Glydeck
·
#155341
·
|
Not to be missed by 7854 fans...
Tek content begins around 8:58. Specifically, this is part 7 of CuriousMarc's series on restoring an Apollo Guidance Computer, but the whole video (and whole series) is great. You really feel like
By
John Miles
·
#155340
·
|
Re: Looking for Sony-Tektronix 318 Logic Analyser Operator's Guide
Debugging I2C data streams, FPGA outputs, video data outputs from graphics chips. Have a CPLD standalone board that takes apart I2C communications and drives an HP logic analyzer. Goes from time to
By
Harvey White
·
#155339
·
|