¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io

Re: 2400 series of scopes -- automatic voltage measurement


 

Are you referring to Page 1-11, Volts, Maximum sine-wave frequency?

This is very confusing because here it actually says greater than or equal to 1MHz.

--Victor

--- In TekScopes@..., Steve <steve65@...> wrote:

Hi Victor,

Yes, I was referring specifically to a 2456B.

TEK specifications indicate that the automatic voltage reading is good
up to 1MHz. Interesting that you are seeing it function up to 200MHz.

Thanks.

Steve

On 2/18/2013 10:33 PM, victor_j_silva wrote:
I assume you mean a 2445A/65A/67 and 2445B/65B/67B.

I know the 24xx Digital Scopes have no such limit.

I just tried using a 1.2V sine wave and was able to measure pk-pk accurately to over 200MHz.

Maybe it depends on the signal amplitude.

--Victor

--- In TekScopes@..., Steve <steve65@> wrote:
Looking for confirmation of my understanding of the Tek specs for
automatic voltage measurement in the 2400 series scopes.

Am I right in understanding that automatic voltage measurement is
spec'ed to 1MHz? And that it is not spec'ed to function accurately above
1MHz?

That's what I get from my reading of the the catalog pages and the
service manual. Am I reading those documents correctly?

Thanks.

Steve


------------------------------------

Yahoo! Groups Links




Join [email protected] to automatically receive all group messages.