I sold an apparently working U800 to a list member from an old 2445. Though the scope seemed to function just fine on initial testing, he later emailed this back:
"I left FB after doing just a quick test at 1ms/Div. After more testing I discovered that it is very noisy at 10X when time base is faster than 5ns/Div after a quick 2 minute warmup. This Horz Amp is not usable."
So I refunded his money. What I take this to mean is that the U800 can be failing or not meeting specs even without total failure. Just something to keep in mind.
Chip
toggle quoted message
Show quoted text
--- In TekScopes@..., "victor_j_silva" wrote:
Sounds very much like the U800 issue.
About six months ago a posted about baking some U800s that had failed this way and was able to rejuvenate them.
I put one of the U800s in a test scope and it's still working to this day. I'm amazed.
--Victor
--- In TekScopes@..., "cmjones012003" wrote:
Hello all,
I haven't posted to this list in a long time but have just been lurking, I'm afraid.
[SNIP]
Thank you in advance
Chris
Cambridge, UK
--