--- In TekScopes@..., "nukescope" <vtp@...> wrote:
- Get your NI GPIB adapter and attach it to the scope
- Put NVRAM protection switch (S1002) to forward position
- Turn the scope on
- Run the PC program
hmm, my first reply was not posted properly, so let's try again.
I've tested your code on TDS754A (fw 4.1e), unfortunately it
didn't worked for me. First of all, when the S1002 is in unprotected
position TDS7xx is no booting, this seems to be the typical case.
While with "protected" position the "m" command you using is not
getting any proper data from TDS.
To double check the results/error, i've edited the code to check
the IDN, which was working, so there is no issue with my setup.
On TDS7xx seems to be a hidden unlock, so i've changed your code
to send PASSWORD PITBULL, but still the "m" command buffer
contains bad data instead of ROM/NVRAM content.