I also note at least one transcription error!! The Start V for .5nS in the second half should of course be 90mV.
toggle quoted message
Show quoted text
Very well spotted on the systematic nature of the offset BTW. I'd been banging my head on the wall (so to speak) with this problem for so long that I completely missed that! Regards, David Partridge -----Original Message-----
From: TekScopes@... [mailto:TekScopes@...] On Behalf Of Albert Sent: 21 January 2012 23:06 To: TekScopes@... Subject: [TekScopes] Re: 7T11 trace shifting left as time/div rotated. Hi David, It takes some time to remember what all those circuits in the 7T11 are doing! The shift in output of U512A in a 5-2-1 sequence corresponds nicely (as should be) to the increase in feedback resistors 10k-25k-50k, ratio 2:3. At 1 ns/div the shift is about 0.5 V and that same shift will appear at the input R647 to the Dot Position Memory. This memory should detect that systematic error and send a correction to the Slow Ramp Inverter. That in turn would (finally) result in a shift of the THT output range to correct the error. This doesn't seem to happen, or not not enough. At the faster sweep speeds U512B and D get switched in and introduce their own offsets. Again the Dot Pos Mem should correct for this. Maybe you can check its operation/calibration. I remember it's not an easy calibration and a lot of compromise is needed. Albert (BTW your packet calculator needs some attention as well...) In equivalent time, sequential mode, the trace is shifting left as I rotate the time/div knob. ------------------------------------ Yahoo! Groups Links |