One quick bit: Don't use that 10meg resistor (or any other ordinary resistor) again for HV measurement.?A typical voltage rating for a half-watt resistor is just a few hundred volts, above which HV will arc through/around it, effectively shorting it out. If you don't want to blow things up, you'll have to use a proper HV probe.
toggle quoted message
Show quoted text
The multiplier hasn't been manufactured for many years, so you'll either have to find a used one somewhere (which itself could be defective), or make your own replacement. Tom On 4/22/2025 12:26 PM, gabrielkrell+tek via groups.io wrote:
My lovely 465 died immediately after I finished some cosmetic repairs. Low voltage test points all look good. No beam, except when I disconnect the ground lead of the HV multiplier as suggested by VintageTek Museum on youtube (). (I also hear some crackling sounds with the multiplier disconnected, so I haven't run it in this state for more than a few seconds.) Could the problem be anything else besides the multiplier? I have a digital scope but no high voltage probe. To measure high voltage DC I have been using a 10MOhm resistor and analog ammeter, but of course that's a significant load. |