Hi folks. I recently purchased a Tek 2247A scope and upon testing it for the first time, it locked up when testing the B sweep with a msg that said
'INVALID INTERRUPT FROM 0993:F082'
When I rebooted, the screen has an indecipherable error message that appears to read something along the lines of 'Part Number 100-xxxx-00' with a bunch of exclamation marks. I couldn't clearly read what the part number as it was out of focus and could get it to focus well enough to read the numbers. The 'Auto Level' and 'Auto' LEDs were flashing which indicates both a RAM and ROM problem according to the service manual. The SGL SEQ LED was also flashing but there's nothing in the service manual that mentions that LED, or at least nothing that I've found.
I let the scope sit for 10 minutes and it booted back up in service mode and gave a failed battery warning, and ran through self calibration. I left the unit on and it locked up after about 10 minutes with the same error as before.
After the reboot I went into the service menu and ran the self test 'until fail' and the test ran for 30 minutes without issue. I also ran through the self calibration once more.
It's now been powered on for a few hours without any problems or locking up and all functions 'seem' to be working as expected.
Thoughts? Would something like this be caused by a battery issue? That seems like an easy fix but if it's something deeper, I'm not sure if I'd want to chance it.
Thanks!
Jay