Thanks, Jean-Paul, Mark, and Tom,
toggle quoted message
Show quoted text
The relaxation oscillator I was referring to is the one that makes the neon flash which is comprised of R3019-C3019-DS3019. I was originally writing the above email when it suddenly occurred to me that after removing the power supply from the scope, I had not connected the dummy load so, of course, it was ticking! I connected the dummy load and the PS came to life normally. I now need to find out what has gone bad in the scope itself. As has been suggested, it's likely a shorted tantalum and, if I had my guess, it's probably one of the ones on the main interface board where the sense line connects. At least now I know better where to look for the problem. Thanks to all who replied, Barry - N4BUQ When there is an overload, the PS shuts down and tries again a bit later. Each |