Mark,
I checked those and one of them is well within tolerance. The other one is just at the high end of its tolerance. I may replace one or both of them but they should be okay for now.
Thanks!
Barry - N4BUQ
toggle quoted message
Show quoted text
Barry,
These are a bleeder for the cathode circuit and partial divider for high voltage
and focus circuit. I replaced mine with 1W 1% types and spaced them off the
board. The 1W types I use are about 1cm in length, not 3,68 x 8,74mm types.
You will find the two 22meg resistors to be well out of tolerance. Use VR37
Vishay types.
Mark