Re: Method to measure HV


 

Barry: Defective HV/CRT replacement/reason to adjust, its rarely needed.

The hi meg HV feedback R in the HV section often drift high.

Easier to check all the megohm feedback R in HV sec. than the -2950V.

Other HV fails are the transformer and mult, bot cause flicker and failure that is total.

Jon