Today¡¯s measurements:
1- Both 6EW6 measure good and strong.
2- Pin 6: +3V
3- Pin 7: +1.6V
4- Pin 8: -4.7V instead of -145V
5- Between Pin 2 and R55: +3V instead of -151V
I would say that it¡¯s very, very wrong¡.
I didn¡¯t locate V56 (10¦¸) in the unit yet.
Also, since I can¡¯t locate SW242B on the schematic, I¡¯m not sure my readings are what they should be.
Meaning that I see that both sides (B side) are always connected no matter the position of the switch. As if the switch was just there for nothing¡. I doubt this is normal, otherwise why even have them go through a switch in the first place¡. Just connect them directly¡