¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io

Re: Type 106


 

On Sat, Dec 18, 2021 at 08:44 AM, saipan59 (Pete) wrote:


On Sat, Dec 18, 2021 at 12:41 PM, saipan59 (Pete) wrote:

I can't think of anything else that would kill the rectifiers...
Correction: Power-rail short could certainly kill a single rectifier. But
having multiple die so easily makes me think of the transformer.

Pete
Well, all the voyages are correct. And I used to have quite nice outputs on all outputs. Current limiting bulbs are not lighting up either. So I don¡¯t think there is a shirt on the PT. Remember that this unit had quite a lot of issues. Maybe that stressed the old original rectifiers quit a bit over time. Once the unit was functioning at full power, the remaining original rectifiers gave under stress. That¡¯s my guess¡­. The new ones seem to be holding up quite well, and again all required voltages are fine. I doubt they would be if any short was anywhere in the PT¡­. Or I¡¯m missing something¡­

Join [email protected] to automatically receive all group messages.