Re: Timebase Question : Auto vs Norm Mode


 

Ah, okay. I didn't know that U520 did that without a trigger so Jeff's correct. That makes a difference and I don't think I saw that in the circuit description.

Thanks,
Barry - N4BUQ

----- Original Message -----
From: "Ozan" <ozan_g@...>
To: "tekscopes" <[email protected]>
Sent: Sunday, December 12, 2021 7:47:02 PM
Subject: Re: [TekScopes] Timebase Question : Auto vs Norm Mode
On Sun, Dec 12, 2021 at 04:33 PM, n4buq wrote:
as long as
C535 is charged, the sweep starts immediately after the previous sweep
finishes and, C535 is discharged only when a trigger is present; therefore,
with no trigger, there's virtually no delay from end-of-sweep to
beginning-of-sweep.

Is that incorrect?
C535 is discharged even with auto-generated sweeps.

Ozan