On Thu, Jul 22, 2021 at 08:28 AM, Richard Peterson wrote:
I use an IET DE-5000 LCR meter. Mine has both tweezers and Kelvin clips (i
installed these to replace the alligator clips that came with it).
I would note that the IET DE-5000 is a rebadged DER EE DE-5000 (I own the DER EE meter). I bought a second alligator clips module (TL-21) and converted it to Kelvin clips. It does pretty much everything that I want except measuring leakage current at operating voltage (needed when working on vacuum tube equipment, but I have equipment for that measurement). I highly recommend it.