Fred,
The voltages on the secondaries of mine with the input set on the high range at 120V mains input: Pins 21 and 22- 6,3V
Pins 12 and 13- 17,4V
Pins 10 and 11- 18,6V
Pins 13 and 15- 90V
Pins 16, 17, 18, 19 and 20- 71, 59, Gnd. 59 and 71V
With slight line variations, the voltages will vary slightly. Voltages were measured with the loads applied and the 6,3V with graticule set at minimum so the a-c voltage at these pins is higher than the nominal 6,3V. This is a 6,3V winding. I would guess the other power transformers you mentioned would work. The 454 type may have a heavier winding for the heaters in the older S/N types. That is fine. The only thing that may be the difference is the current and slight physical size difference. If you can get one, it should work fine.