And the algorithm is the same regardless if it's HP or Tek, so
either can be used on either.
Paul
toggle quoted message
Show quoted text
On Sun, Mar 14, 2021 at 12:21:29PM -0700, Mlynch001 wrote:
On Sun, Mar 14, 2021 at 12:51 PM, stevenhorii wrote:
I know that HP (sorry!) uses signature analysis for troubleshooting some of
their computing counters. Does Tek specify signature analysis for
troubleshooting of their scopes with digital processing and control?
Steve,
Yes, the 308 is used extensively for signature analysis on the 468. It is part of the ¡°recommended¡± test equipment in the Service Manual. I just used mine to repair a broken 468. Still a useful tool.
--
Michael Lynch
Dardanelle, AR
!DSPAM:604e6246224641159887144!
--
Paul Amaranth, GCIH | Manchester MI, USA
Aurora Group of Michigan, LLC | Security, Systems & Software
paul@... | Unix/Linux - We don't do windows