Jon,
Good suggestion... two 50ohm cables, same nominal length, split at the oscillator and fed into channels 1 and 2 gave the exact same voltage and phase. Even at 10x mag they overlaid each other.
So the probes are the problem!Have 2 P6137 on the way and will replay the game then. :-)
Regards,
Mark