Hi Jon,
The 2465 supply is such a reliable supply that there
should be no need to keep spares. Recap yours, replace
the RIFA X2 caps (0.068uf), and it will go the next
40 years without a hitch. It is rare, rare, rare that
I have to fix anything in these supplies that isn't
a capacitor. I replaced a bridge rectifier a couple
of times.... but that failure blows fuses. I can't
remember ever having to do anything more.
-Chuck Harris
Jean-Paul wrote:
toggle quoted message
Show quoted text
Hello all restoring a fine 2465B opt 06, 09.
The PSU needs recapping and may have other faults.
I would like to have a spare as I have other units.
If anyone has a spare PSU that works, I am interested to get one.
The units from Sphere, Qservice etc are too costly, a big fraction the value of the 2465B!
I have some TM500 and 7000 plugins so perhaps a swap is possible as well.
Many thanks!
Jon