Hi George,
There are rules, and there are rules. Behavior when working
on a 40KV power line is very different than behavior when
working on a 40KV CRT anode supply. One can source enough
current to vaporize the probe, and the other can merely taunt
the probe with its cross words...
These probes are meant for low current applications, and to be
held by hand. There are sever warnings about not using the probe
on high current or without the grounding clip attached to a
ground... for obvious reasons.
-Chuck Harris
george edmonds via Groups.Io wrote:
toggle quoted message
Show quoted text
Hi Chuck
I am quite amused by the 40KV probe as rule one is that you do not hand hold such an item when applied to power.
Best of luck
George
On Friday, August 16, 2019, 11:02:22 PM GMT+1, Chuck Harris <cfharris@...> wrote:
Hi George,