tom jobe
If you are talking about the black cover over the two largest capacitors, there is a prong that goes down in the middle between the two bumps, the prong has a hook on one side of it that latches the cover in place. You deflect the prong to the side a little bit and the cover comes off in your hand. Maybe wait until you have the power supply out on the bench before trying to remove the black cover?
toggle quoted message
Show quoted text
Those two large capacitors never seem to give any trouble in a 24x5 but have a look anyway and check the ESR if it is easy for you to do. Replace all of the smaller caps regardless of how they look or the ESR checks out. I see you have been warned about the schematic errors on two of the capacitors, don't miss this problem. There is excellent help available here on Tekscopes for the 24x5 scope family. On 8/3/2019 4:13 PM, n4buq wrote:
I was using my 2445 today when I heard a strange sort of thump noise coming from inside the scope after which I startettd smelling a burning odor. I had a few pieces of gear powered up at the time but quickly could tell the smell was coming from the 2445. |