I've tried cleaning U500 and U900 to no avail, and then I swapped U900 and U700 again to no avail. Will continue searching for sweeps that might work and looking at that opamp.
toggle quoted message
Show quoted text
On Tue, Mar 19, 2019 at 01:15 PM, Siggi wrote:
On Tue, Mar 19, 2019 at 8:54 AM <thespin@...> wrote:
It¡¯s not. The proper lights come on suggesting the scope is trying to run
the B sweep, but it isn¡¯t running.
I would start by pulling, cleaning and re-seating U900. Second perhaps swap
U900 and U700.
If that doesn't help, you might be able to narrow this down a bit by
experimenting with various A/B sweep speed combos and B delay/trigger
settings. If there's any combo that will produce a sweep, then you can
start eliminating problems.
If there's no combo that'll start the sweep, then I'd focus on the constant
current generator op-amp (U910A in my 2467 schematic), and then on the
delay ref outputs from the A5 board.