from Tim P (UK)
I'm with Craig on this one - I had same problem with a 7613 blowing
instrument fuse,
and also a 'scope from 'The Other People' <g>
Both had failed bridge rectifiers.
I may have strained the 7613 by running a 7D20 in it, as discussed here
previous.
regards
Tim
On Mon, 19 Nov 2018 at 21:12, Craig Sawyers <c.sawyers@...>
wrote:
But then, after about 10 minutes it was on... all of a sudden, I heard a
"pop", and all lights of
the scope
went dark (including the Power Light) and I had to leave (didn't have
chance to open it).
Bridge rectifier?
Craig