OK, here's where I am now: Power light comes on, and all LV DC voltages
toggle quoted message
Show quoted text
are within tolerance except +5 V, which reads ~+4.4 V. Ripple is out of spec on all except for +130 V. +5 V rail looks like a high duty ratio dipping from 5 V down to about 2 V periodically, synchronous with the AC mains. I figured a tantalum capacitor on the 5 V rail was a nominal short, but I don't see any tantalums anywhere in this scope, a late model 7603, Serial Number B345179. Just ceramic discs and aluminum electrolytics. Any ideas on where to look? I figure the crap on the 5 V rail may be messing up the others - make sense? Thanks. Jim ------ Original Message ------
From: "Al Holt" <grovekid2@...> To: [email protected] Sent: 6/25/2018 4:21:40 AM Subject: Re: [TekScopes] Dead 7603 You've got a dead 7603 with no lights. Definitely look at the low --- This email has been checked for viruses by AVG. |