On Thu, 5 Jul 2018 at 02:53 Roger Evans via Groups.Io <very_fuzzy_logic=
[email protected]> wrote:
I tried my very early PG506 with a 7904 / 7A29 or 7A16p / 7B92A. I can't
measure any jitter between the trigger output and the fast rise outputs at
the 50-100psec level. The rise time of the high amplitude output into
50ohm is about 10nsec and due to the time delay between the trigger and
high amplitude pulse I have to use the delayed sweep on the 7B92A to get to
1nsec/div so more uncertainty but the jitter is at the 100ps or less
level. 1.5nsec sounds like something badly wrong.
Thanks, I'm looking at the output of the pulser which is after the hi-ampl
output. I should look at the output of the PG506 directly.