On Thu, 28 Jun 2018 at 07:53 Albert Otten <aodiversen@...> wrote:
BTW: I had no patience to view the whole video. Bu I saw at 32-33 minutes
that the AC input voltages to the bridge rectifiers are measured. For +15
that was 1.3 V. I find this hard to believe. Apparently then there is
nearly a shortcut loading the transformer winding. I guess this would
immediately blow the main fuse?
Yeah, I rewound to watch this again. I don't think he was making contact,
as you see the voltage he measures spike to ~1.5V with only one of the
probes touching, and basically wandered around that value while he was
poking at it.