Hi Tom,
Thanks for the reply. I am a bit puzzled by this one. I have a great 465B (which I'm using to try to fix the 2215) and a 2232 storage scope that works fine. This one is a puzzle. When I first started on this one, if I moved the B Trigger Level Control all the way clockwise, I had a trace but now that's stopped working. I keep thinking that's a clue but so far, no luck. I suspected a bad capacitor but I have checked every one in the path multiple times and they all seem fine. I have checked voltages expecting to find something way off but so far, no luck.
If you think of anything to check, let me know. I will appreciate it!!
Steve