Replacing 402 hot water heater
Arcadia's original Raritan 12 Gal. hot water heater has rusted out and is leaking, so it is time for a replacement.? We currently do not have a mixing valve, so I am planning to add that as well as a 3 way valve for winterizing.
?
Instead of simply replacing the Raritan, I am wondering if anyone has experience to share with using an Isotemp or Quick heater as a replacement. I see the Isotemp is stainless and plastic, comes with a mixing valve, and is less expensive than the Raritan. It looks as if either of those might require extending or replacing the heat exchanger hoses.?
?
Thanks in advance for any advice.
--
-- Jim Harman Arcadia S402 #2 Southport CT |
I replaced the Raritan with a 5 gallon Isotemp with the mixer.? Has worked well, 5 gallons seems to be enough hot water.? It is plumbed with the engine cooling system and has a 110 heater.? Mike Sabre 402 #37 Lake Ontario
On Thursday, March 13, 2025 at 11:49:44 a.m. EDT, Jim Harman via groups.io <j99harman@...> wrote:
Arcadia's original Raritan 12 Gal. hot water heater has rusted out and is leaking, so it is time for a replacement.? We currently do not have a mixing valve, so I am planning to add that as well as a 3 way valve for winterizing.
?
Instead of simply replacing the Raritan, I am wondering if anyone has experience to share with using an Isotemp or Quick heater as a replacement. I see the Isotemp is stainless and plastic, comes with a mixing valve, and is less expensive than the Raritan. It looks as if either of those might require extending or replacing the heat exchanger hoses.?
?
Thanks in advance for any advice.
--
-- Jim Harman
Arcadia S402 #2 Southport CT |
开云体育My 362 had same Isotemp setup when I purchased 10 years ago.? Woks great, all the HW we need.On 3/13/2025 11:55 AM, Mike via
groups.io wrote:
--
Dave Short SV One Timer 1997 S362 Mt Desert, ME |
toggle quoted message
Show quoted text
My 362 had same Isotemp setup when I purchased 10 years ago.? Works great, all the HW we need. --
Dave Short SV One Timer 1997 S362 Mt Desert, ME |
Thanks David and Mike, I am not at the boat now to measure the space. How are your Isotemp heaters mounted - sideways, i.e. with the pipes pointing toward the shower, or with the pipes pointing forward? And did you need to extend or replace the hoses to the engine, or did the original hoses fit? On Thu, Mar 13, 2025 at 1:33?PM David Short, SV One Timer, 1997 362, Mt Desert, ME via <dhs.short=[email protected]> wrote: -- --Jim Harman --
-- Jim Harman Arcadia S402 #2 Southport CT |
开云体育Pointing forward towards shower in 362. Located in lazaretteI did not do install so cannot tell on the hoses On Mar 13, 2025, at 5:31?PM, Jim Harman via groups.io <j99harman@...> wrote:
--
Dave Short SV One Timer 1997 S362 Mt Desert, ME |
Yes it went in but on a slight angle with all the fixtures? facing the head. This made the connections all accessible from either the stairs or the head access panel.? I put a piano hinge on the bottom step so it could be easily opened for access. Just like the winch storage stair.? It also gave me a place to store the empty wine bottles and beer cans.? The hoses were long enough to be connected.? Having the stair access makes it very easy disconnect the water system to install a bypass for winterizing and draining.? Mike Sabre 402 #37?? Lake Ontario
On Thursday, March 13, 2025 at 05:31:38 p.m. EDT, Jim Harman via groups.io <j99harman@...> wrote:
Thanks David and Mike, I am not at the boat now to measure the space. How are your Isotemp heaters mounted - sideways, i.e. with the pipes pointing toward the shower, or with the pipes pointing forward? And did you need to extend or replace the hoses to the engine, or did the original hoses fit? On Thu, Mar 13, 2025 at 1:33?PM David Short, SV One Timer, 1997 362, Mt Desert, ME via <dhs.short=[email protected]> wrote:
|
Thanks for that information, Mike. Would you happen to have a photo that shows the installation? Thanks again. On Fri, Mar 14, 2025 at 9:07?AM Mike via <mikecnewbury76=[email protected]> wrote:
--Jim Harman --
-- Jim Harman Arcadia S402 #2 Southport CT |
I can send a picture later. My boat is on an island and I have to wait for the ice to go out before I can get there.? Give me a couple of weeks.? Mike
On Saturday, March 15, 2025 at 11:35:05 a.m. EDT, Jim Harman via groups.io <j99harman@...> wrote:
Thanks for that information, Mike. Would you happen to have a photo that shows the installation? Thanks again. On Fri, Mar 14, 2025 at 9:07?AM Mike via <mikecnewbury76=[email protected]> wrote:
--Jim Harman --
-- Jim Harman Arcadia S402 #2 Southport CT |
Good tip on the?drain, Jim. Do you have the original Raritan heater? Arcadia's has a 3/4" tee on the cold water inlet with one end attached to the heater and a plug in the other end. I think this is supposed to be the drain,?but I have not been able?to remove it due?to the?tight space and dried?up pipe dope. The side srm on the tee goes to a bushing and a 1/2" check valve. I loosen the hose clamp on the other side of the valve and unscrew it for winterizing.and draining. When the check valve is loose, it is easier to remove the cold water hose from the barb on the other end and connect it to the hot water hose. I then blow out the system with compressed air and put about a quart of pink antifreeze into the hot water connection using a short hose and funnel,?as described in the Raritan manual.. On Sun, Mar 16, 2025 at 7:43?PM Jim Gregory via <jgregor1.jg=[email protected]> wrote:
--Jim Harman --
-- Jim Harman Arcadia S402 #2 Southport CT |
Hi Jim,
Yes the original Raritan 12 gallon unit. When winterizing, I pull both cold and hot hoses off and join them together. Then I have to disassemble the bottom piping because that check valve down there will not let the tank drain. It is a royal pain! I keep saying I am going to improve it, but then I just put it back together the way it was. I don't love draining all that water in that compartment, but so far so good. I don't put antifreeze in the tank at all. No need to when it's about empty. A drain, with a hose barb and hose leading to the bilge would be REAL nice, but you know how much fun it is to work in that little space. A couple of years ago I took the shower door off to winterize it, and it now lives in my garage loft. It's just not needed, but with it you can SAY you have a dry head. I would be fine with a 6 gallon tank. That size got us by for years, and lighter for racing.
--
Jim Gregory Sabre 402 #32 Milford CT |
Thanks Jim, we have decided to change to the Isotemp 20 l (5.3 gal)?? heater for the replacement. It is about half the price of the Raritan and includes a drain and tempering valve. It has a stainless tank so rust should not be an issue. I will let you all know how the install goes. On Thu, Mar 20, 2025, 3:46 PM Jim Gregory via <jgregor1.jg=[email protected]> wrote:
--
-- Jim Harman Arcadia S402 #2 Southport CT |
开云体育5.3 gal ? That doesn’t seem to be much hot water. Ours is 12 gal on the Delphia 40.?Please consider the environment before printing this email. Thank you. On Mar 20, 2025, at 4:15?PM, Jim Harman via groups.io <j99harman@...> wrote:
|
5.3 is enough for two people that are cruising. It's always good to be conservative with fresh water use on a boat. I got by nicely with heaters of that capacity for years. My 12 gallon tank is an extravagance that I would not replace if needed. 5-6 gallon is fine.
--
Jim Gregory Sabre 402 #32 Milford CT |
toggle quoted message
Show quoted text
On Mar 21, 2025, at 9:01?AM, Jim Gregory via groups.io <jgregor1.jg@...> wrote:
|
to navigate to use esc to dismiss