Re: #qmx #firmware 1_00_017 AGC, S-meter, LPF sweep #qmx #firmware
Thank You, Thank You, Thank You! Hans, you are the best. Mike Krieger
By Mike Krieger · #118172 ·
Re: oscilloscope use
Personally I bought a Siglent SDS-1104XE which is a very capable 100mhz 4 channel unit. It’s has loads of features, an excellent display and is expandable to 200mhz. Very pleased with the purchase
By Gerald H. · #118171 ·
Re: QDX - No transmit on 80M #qdx
OK! Glad that worked! A word of caution, though. Your power supply is pretty high for running a 12V QDX. You might want to bring it down a couple of volts, or perhaps two silicon diode drops in
By John Z · #118170 ·
Re: QDX - No transmit on 80M #qdx
That did the trick! I looked closely at the joints for L1 and L2 and noticed that one of L2's? pads (nearest IC3) wasn't fully flowed around the wire. It passed the continuity check when I assembled
By K1QLN, John · #118169 ·
Re: #qmx #firmware 1_00_017 AGC, S-meter, LPF sweep #qmx #firmware
Thank you Hans! I have been waiting for AGC to take this out on POTA again!!
By Nic Heath · #118168 ·
Re: #qmx #firmware 1_00_017 AGC, S-meter, LPF sweep #qmx #firmware
So, got a QSO in the log and the good news is the AGC seems to largely work, particularly on Rx. However it has introduced a very sharp tick at the start of each dit and dah on Tx.? This is very
By Danny Bower · #118167 ·
Re: #qmx #firmware 1_00_017 AGC, S-meter, LPF sweep #qmx #firmware
Hi Bev. See my notes in this thread on how to roll back to 016 (or whatever you were running before the update). You'll have to remove the 4 bottom screws (2 on each side) to pop the bottom cover
By Roy - KI0ER · #118166 ·
Re: QDX - No transmit on 80M #qdx
John The usual culprit causing no output on one band is a bad solder joint at one or more toroid leads in the LPF for that band. That is usually the result of inadequate enamel removal from the
By John Z · #118165 ·
Re: QMX shows high SWR
Ok, forget my post, it was a bad contact in a BNC/PL adapter.
By roebi@... · #118164 ·
Re: #qmx #shipping update #shipping #qmx
*" . . . a carpenter building two new 90 x 270cm tables . . . "* If you can procure motorized leg sets locally, consider having these built as standing desks. Your team will greatly appreciate them.
By Jim Idelson · #118163 ·
Re: #qmx #firmware 1_00_017 AGC, S-meter, LPF sweep #qmx #firmware
Yes, I also confirm the new 017 is alive and working! I'm very excited to try out the new AGC functionality!? Thanks Hans! 73 Roy - KI0ER
By Roy - KI0ER · #118162 ·
Re: #qmx #firmware 1_00_017 AGC, S-meter, LPF sweep #qmx #firmware
Except that the COM access and the virtual directory do not appear any more....... Bev COAA
By algarveastronomy · #118161 ·
Re: #qmx #firmware 1_00_017 AGC, S-meter, LPF sweep #qmx #firmware
Hans, That fixed it. Tnx! Paul, W9AC Sent: Friday, February 16, 2024 10:20 AM To: [email protected] Subject: Re: [QRPLabs] #qmx #firmware 1_00_017 AGC, S-meter, LPF sweep Hi Roy,
By Paul Christensen · #118160 ·
Re: #qmx #firmware 1_00_017 AGC, S-meter, LPF sweep #qmx #firmware
That seems to be working now Hans :)
By Danny Bower · #118159 ·
Re: #qmx #firmware 1_00_017 AGC, S-meter, LPF sweep #qmx #firmware
Hi Roy, all Profound apologies are hereby offered. I would love to be able to tell you that I just fired the entire development time however, I already fired them last time. Embarrassment...
By Hans Summers · #118158 ·
Re: #qmx #firmware 1_00_017 AGC, S-meter, LPF sweep #qmx #firmware
I was able, using the wire jumper, to roll back to 016 Firmware, and my darling QMX appears happy again. It's nice that one only needs to remove the 2 bottom screws on each side of the enclosure to
By Roy - KI0ER · #118157 ·
V17 Signal meter #qmx
Hi Hans, In IQ enabled, digital mode the Signal strength meter is not display.? On my QMX it only displays the Signal strength in CW mode with IQ set as disabled.? Don't know if this is by
By timo.vandermerwe@... · #118156 ·
QDX - No transmit on 80M #qdx
Hi All, I have a rev 3a QDX (80-20 model, firmware 1.10) that I built back around 10/2022. I used it more or less continuously for 6mo after building it, with great results. I wrapped T1 for 12v and
By K1QLN, John · #118155 ·
Re: oscilloscope use
Looks like it's still available or at least it's current iteration. Rigol DS1102Z-E - Two Channel / 100 MHz Digital Oscilloscope https://a.co/d/i9XyKEG Roy WA0YMH wrote:
By Roy Appleton · #118154 ·
Re: #qmx #firmware 1_00_017 AGC, S-meter, LPF sweep #qmx #firmware
Hi Roy Yes I deleted 1_00_017 from the page... There's a division-by-zero someplace when the new parameter settings are zero. Ouuuuffff... OK I am figuring it out then I will stop that... 73 Hans
By Hans Summers · #118153 ·