160m image rejection is a known issue and I will fix it as soon as I have done the SSB firmware update. It's not a hardware issue, it's firmware. If all the other bands are correct then you don't need to worry!
73 Hans G0UPL
On Thu, Sep 26, 2024 at 3:12?PM Trevor Shackleton via <trevorshackleton=[email protected]> wrote:
My newly built QMX+ is showing poor image rejection in the test suite, but only when for 160m, other bands look OK.
The image at 160m indicated -3.7, with both wanted and image around -16.
Looking at the Test ADC I/Q, the two signals show almost in phase when they should be 90deg apart for quadrature (other bands show quadrature as expected). The Q waveform is?
only about half the amplitude of the I waveform (again only on 160m, other bands having equal amplitude as expected).
I suspect both the above are different views of the same issue, but I am not sure where to look to further investigate the cause.