Re: QDX xmit one flash


 

Ok. So no output at the dummy load.

I would now start working backwards from the BNC socket centre pin,through the LPFs to the PA, checking for continuity. QDX turned off, ok!

I suspect you have a poorly soldered toroid.

Roger

Get
On 24 Aug 2023, at 08:13, Wayne Greene <wayne.greene489@...> wrote:

Correct, pulsing. I didn't hold it the keys down until you suggested that, lol. OK, my dummy load does have a power meter attached. It's analog and the needles do not move at all. I'm not sure about measuring the voltage across the dummy load, though. That I've never done.