Hi Ed,
So far, the same Icom string selection has worked with all Icom
rigs. I haven't had a report specifically on the 736 but it should
work. Just select Icom from the rig options.
Chuck, I did some digging through my notes and found a report of
working settings for the IC 706 MK II G with my software.
The settings are:
Baud rate: 19.2K
Parity: None
Data Bits: 8
Stop Bits: 1
Power Selected: DTR (that will depend on your interface)
I hope this helps. Please let me know how you make out.
73,
Scott, N3FJP
snkdavis@...
www.n3fjp.com
Serving the Amateur Radio Community with general logging and
contesting software since 1997.
--- In N3FJP_Software_Users@..., "Edward Leicester"
<kg4qmi@e...> wrote:
I see in the list of rigs that the IC-736 is not listed. Does
anyone know if it will work?
Ed/kg4qmi
------------------------------------
Edward Leicester
Reg. 1 Director
North Carolina Baptist Men
-----------------------------------
EC-Perq. County, Area 1
NC-ARES
Hertford NC
252-426-7246
KG4QMI/FM16
----- Original Message -----
From: k9plx@m...
To: N3FJP_Software_Users
Sent: Friday, July 25, 2003 11:25 PM
Subject: [N3FJP_Software_Users] Can't get ACLog to read freq &
mode
Greetings to the group.
I'm a long-time user of ACLog who has just purchased the cable to
connect my rig so I can read the frequency and mode directly into the
log. I've tried everything I can think of and so far am unsuccessful;
I could sure use some suggestions.
The setup: PC is an older model IBM ThinkPad laptop Pentium II
running Windows XP Professional. Rig is Icom IC706MarkIIG. I have the
cable from W1GEE and it is connected to the serial port of the PC and
the remote jack on the back of the 706.
In the Interface Setup window of ACLog, I have set to Comm Port
1, 19.2 baud (the rig is also set to 19.2), connection power to DTR
(I've also tried RTS). I've set the string to read frequency to "FE
FE 58 E0 03 FD" and the string to read the mode to "FE FE 58 E0 04
FD" (values come from the 706's manual). Having no idea what the
other values should be, I've tried them all, I think.
The response is always "No Response" in the Frequency window,
either "No Response" or nothing at all in the Mode window, and a
running string of garbage, which changes as I change the tuning dial
on the rig, in the "Unprocessed data returned" window.
Does any other Icom owner have any hints for me?
Thanks,
Chuck, K9PLX
Yahoo! Groups Sponsor
ADVERTISEMENT
To unsubscribe from this group, send an email to:
N3FJP_Software_Users-unsubscribe@...
Your use of Yahoo! Groups is subject to the Yahoo! Terms of
Service.