Re: Kenwood SM-230 Station Monitor


 

?
The AIP function bypasses the Rx RF amplifier and feeds the Rx signal directly to the mixer, resulting in less gain on Rx...That's why you see less signal on the SM-230 when the AIP is on...
?
73...Jordan VE6ZT

----- Original Message -----
Sent: Monday, March 24, 2025 7:44 AM
Subject: Re: [Kenwood-Amateur-Radio] Kenwood SM-230 Station Monitor

Right. It may not bypass it, as I do see faint activity on the scope, but the signal emitted from the IF out is definitely weaker.