Locked Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY


 
Edited

¿ªÔÆÌåÓý

Rick , so have you or anyone looked at switch-off transients of the original switches? And also contact bounce on closing for other reasons?

Re some SSRs see

??

?

pdf???? 3? -----??

Later they call for peak switching for transformers

don

?

From: [email protected] [mailto:[email protected]] On Behalf Of Rick W4XA

?

¡­¡­¡­¡­.It appears that some experimentation could? in order.

If you have a dual trace scope, you can easily measure the input voltage & current on the transformer primary and observe the phase difference between the 2 in real time and during switching events¡­¡­¡­


--
don??? va3drl