Locked Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY


 

¿ªÔÆÌåÓý

Scott,

?

I worked on three phase power supplies that had some premature transformer failures.

?

The engineers had us install MOVs across the primary windings for all three phases.

?

Never seen another transformer failure afterwards.

?

Dave

W9HF

?

From: [email protected] [mailto:[email protected]] On Behalf Of Scott Petersen
Sent: Thursday, July 4, 2024 3:16 PM
To: [email protected]
Subject: Re: [HallicraftersRadios] HT-37 transformer failure due to rapid STBY-->OFF-->STBY

?

I wonder if a MOV could be somehow used to soften the inrush, if not one perhaps 2 in some kind of toggle arrangement.

?