Re: Sx100 question on 50.5 kc alignment


 

¿ªÔÆÌåÓý

Thanks Dan, I missed that one.


From: [email protected] <[email protected]> on behalf of Dan <pitfit@...>
Sent: Monday, April 1, 2024 8:44 PM
To: [email protected] <[email protected]>
Subject: Re: [HallicraftersRadios] Sx100 question on 50.5 kc alignment
?
?Test point B is DC. Keeping the displayed voltage around 1 volt or so isn¡¯t super critical during the 50.5 alignment ?but, in general, you usually want to keep the injected and observed voltages pretty minimal to get the best alignment, unless the manual calls for a specific voltage or level. Pay attention to your AGC switch. I don¡¯t quickly remember if the manual says to have it on or off for the 50.5 alignment (probably off, I think) but on or off will make a huge difference on the prevailing voltage at test point B so make sure yours is set right.

Can you reduce the level on your sig gen? If you can¡¯t get down to 1-2 volts or so you probably are injecting too much 50.5 kHz or your AGC switch is not set right. You should be able to keep test point B easily in a ~1-3 VDC range and peak T3-T6 from there.

I keep an old HP-606A around just for the 50 kHz Drakes and Hallicrafters. I set and confirm a 50.5 output using a scope with a counter function. The 606 is dead stable and warms the shop in the winter.

Dan
WB4GRA


On Apr 1, 2024, at 8:37?PM, waltcates <cateswa@...> wrote:

?
You are getting DC and AC mixed.

The 1 volt rms is the ac signal.

The dc component (10 to 12 volts) is the dc bias developed by the detector diode tube.

Go back to test point, set your meter on ac and try again.


Walt Cates, WD0GOF
?
A majority of acceptance is not proof of correctness.



From: [email protected] <[email protected]> on behalf of Keith <kd4avp@...>
Sent: Monday, April 1, 2024 7:25 PM
To: [email protected] <[email protected]>
Subject: [HallicraftersRadios] Sx100 question on 50.5 kc alignment
?
Apparently I only thought my alignment was successful.
Think I either interpreted something wrong or there is something more going on.?
Inputting a 50.5kc signal at T1 on pin number 1 as directed in the manual.?
I am using a Heathkit IG 5282 signal generator adjusted as close to 50.5kc I can get.
Used my oscilloscope to get that on target.?
Pulled the 1 osc conversion tube as recommended.?
Using my VTVM connected at point B (R48, R49 & C81 all connect on a terminal strip at this point), was monitoring the DC voltage.
I was adjusting T3, T4, T5 & T6 (all 50.5 IFs) to maintain 1 volt reading on the VTVM.
I never got anywhere close to 1 volt DC.
It was actually closer to 10 and 12 vdc.
What am I missing here?
I did manage to get it down to 7 volts but it was not completely stable there. But I did expect it to vary a little bit.
In my mind, I must have been thinking it should only vary by 1 volt....not actually be 1 volt.