Date
Re: 5065A rubidium standard parts
Hello jfphp, I have a complete HP5065 apart? from two modules 1)? A13 BUFF AMP 05065-6020 2)? A10 OSCILLATOR? ?00105-6013 Can you help?? TNX Boutsen Jan? ? ? ON4MMW 3500?
By Jan Boutsen · #92539 ·
Re: Wanted: Paper copies of manuals for HP 35665A Dynamic Signal Analyzer
Hi Dave, I'd love to get these as well. I have some scanned copies if this helps you? In case you end up with multiple copies I'd be willing to purchase unnecessary sets from you. I have these rare
By Leo Bodnar · #92538 ·
Synthesizer module in ESG series E4435B
I have E4435B signal gen from ESG series that loses output in certain parts of its output range 250..350MHz, 500..700MHz, etc. The problem seems to be in the VCO or its PLL loop.? Its output is
By Leo Bodnar · #92537 ·
Re: HP Basic help
Thank you Leo ! Am 10.11.2018 um 23:56 schrieb Leo Bodnar:
By Dr. Matthias Weisser · #92536 ·
Re: Wanted: Paper copies of manuals for HP 35665A Dynamic Signal Analyzer
[email protected] wrote: I assume you have have not worked with the HP 70000 series. An HP 70000 series setup tends to be really heavy. ? I would agree the 35665A is heavy, but the 70000
By Dr. David Kirkby from Kirkby Microwave Ltd <drkirkby@...> · #92535 ·
HP 8922
Does anyone have any information on this test set beyond the Assembly Level manual? This manual references block diagrams by figure number, but, there are no block diagrams in the manual. This was
By Glenn Little · #92534 ·
Re: ´ð¸´: [HP-Agilent-Keysight-equipment] R80 OF HP 8904A Power supply board
Hi Adrian: Many thanks for your picture, now I am sure the resistor which damaged is R11, it was my fault to confuse it with R80. I'm going to replace new one on my 8904A, thanks a again. Best
By Jar Sun <ahhuic@...> · #92533 ·
Re: What happens if a "calibration date" is in the firmware?
According to someone I know, who is not the sharpest knife in the draw, Fluke consider adjustments as repair and charge extra. Some third party companies can test if an item it within specification,
By Dr. David Kirkby from Kirkby Microwave Ltd <drkirkby@...> · #92532 ·
Re: What happens if a "calibration date" is in the firmware?
If I send something in for calibration and it meets all specs then I would expect a cal sticker, certificate and if I asked for it the data. I would be annoyed if a manufacturer came back to me and
By Peter Gottlieb · #92531 ·
Re: HP Basic help
I know few ways of getting LIF formatted floppies converted to plain text format: 1) using http://www.hp9845.net/9845/projects/hpdir/ 2) making floppy image with TELEDISK
By Leo Bodnar · #92530 ·
What happens if a "calibration date" is in the firmware?
I know by international agreement that calibration is a comparision to known standard - not adjustments. But someone I know sent an instrument to Fluke for "calibration". It was in spec, so no
By Dr. David Kirkby from Kirkby Microwave Ltd <drkirkby@...> · #92529 ·
Re: HP Basic help
Nice! Is it also possible to run the required software on an 16702?
By Andy ZL3AG · #92528 ·
Re: 5065A rubidium standard parts
I'd love to get a paper service manual for the 5065A.? If you can get back to me, I'd like to see what we can work out. Richard Parrish
By Richard Parrish · #92527 ·
Re: HP Basic help
Thank you very much Leo ! you have a very fine system here. Really looks impressive. This emulator also looks good. http://www.leobodnar.com/files/HP9000-BASIC.mp4 Have you been able running this
By Dr. Matthias Weisser · #92526 ·
Re: 8663A Status Display Codes and Display Issue
Swap the digit with another (in the board), and see if the problem follows the swap. The LED's are epoxy encapsulated, and over time the epoxy shifts a bit, opening connections, and causing problems
By Chuck Harris · #92525 ·
Re: 8663A Status Display Codes and Display Issue
As for the missing display, it may be a thermal sensitive intermittent so you could try using freeze spray on the various chips on the display board once it warms up and all displays work. That may
By Peter Gottlieb · #92524 ·
8663A Status Display Codes and Display Issue
Hi Guys, I got a "new" 8663A since I want to do phase noise measurements of oscillators. So I got this unit, and it seems to work nice, but I have two minor issues: a) in the status display, I always
By Tobias Pluess · #92523 ·
Re: HP Basic help
Software and documentation is also available here: http://www.hpmuseum.net/display_item.php?sw=441 Cheers Leo
By Leo Bodnar · #92522 ·
Re: HP Basic help
It's not lost.? You can run HP9000 series 200 emulator https://sites.google.com/site/olivier2smet2/home/hp200-300 and use software from http://www.hpmuseum.net/exhibit.php?swc=6 if you just want to
By Leo Bodnar · #92521 ·
5065A rubidium standard parts
For sale various parts for the HP Agilent 5065A : boards including A1 synthesyzer assy, Rb lamps, Rb filters, 5 Mhz oscillators, paper manuals...
By jfphp · #92520 ·