CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 Ω) 350C
- Attenuator set (600 Ω) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
How to clean NiCd batt leak residue
Hi there,
When I opened up my 8672A synthesized CW generator, I found the NiCad batt pack was leaking. It was clean few years back. I removed it immediately but it left blueish and sort of oily
By
Calvin Guan
·
#86266
·
|
Re: Plan to deep cleaning my gear
?????? Liquid dishwahing detergent like Dawn is safe for nearly everything. You have to test paint. Use a cotton swab somewhere where a mark won't show. Naphtha is safe for many paints but not
By
Richard Knoppow
·
#86265
·
|
Re: Plan to deep cleaning my gear
I want to clean 8350B/83592B sweep source, 8510 Vector Network Analyzer display and I/F sections, and the S-Parameter test set, and a 8566B spectrum analyzer(RF and Display).
The 8510C panel is
By
Calvin Guan
·
#86264
·
|
Re: HP items for sale
Hello,
no problem. If you ever change your mind let me know
With best regards
Tam Hanna
---
NEW: Enjoy electronics? Like seeing oscilloscopes get repaired? Please subscribe to my new YouTube
By
Tam Hanna
·
#86263
·
|
YIG pinout
Does anyone have the pinout for the 5086-7267 YIG oscillator handy?
My google-fu seems to be weak today.
Thanks,
-Dave
--
Dave McGuire, AK4HZ
New Kensington, PA
By
Dave McGuire
·
#86262
·
|
Re: 3585B Spectrum Analyzer
So far I've removed all the boards I could that were relatively easy. I have not touched the ones that are under a metal panel identified as A and then a number. A31 or A32 for example.
I'm no
By
ve3poa@...
·
#86261
·
|
Re: Plan to deep cleaning my gear
?????? You have not said what equipment you want to clean. It does make a difference. I have detailed the method of washing employed at the -hp- service center a great many years ago but this
By
Richard Knoppow
·
#86260
·
|
Re: Plan to deep cleaning my gear
I find that Ronson lighter fluid, which is just naptha works very well.? This includes not only label goo, but a wide range of "dirt".? It's mild and doesn't hurt plastics (at least not any that
By
Daun Yeagley
·
#86259
·
|
Re: HP items for sale
Hi Tam, No, thank you.
Frank
By
Frank Hughes
·
#86258
·
|
Re: Plan to deep cleaning my gear
The only thing I'd wash with water and soap is the front panel itself
(completely removed from the instrument, and any pcbs or wiring harnesses
removed from it), any knobs once removed from the pots,
By
Andrew Hakman
·
#86257
·
|
Re: YIG device failure modes
Tobias,
The main coil is for pretune -- which brings the center frequency of the YTO to the YTO PLL's capturing range which is usually +/- 20~30mhz around the CF. The FM coil is used to perform the
By
Calvin Guan
·
#86256
·
|
Re: Plan to deep cleaning my gear
Thank a lot for all your inputs guys! My instruments work very well for their age. I just wanted to make them great again:)
After reading your posts, I figured I will stay away from using any
By
Calvin Guan
·
#86255
·
|
Re: Question about HP3586B and measuring Power.
The 3596 was used to measure carrier levels in a multiplexed system at 75 ohms. The 75 ohm input would be used to terminate a 75 ohm output directly. The 10k input would have been used to bridge a
By
Tom Miller <tmiller11147@...>
·
#86254
·
|
Question about HP3586B and measuring Power.
One of the inputs on the 3596B is a 75ohm, another is a 10k ohm//50pf.
I can understand with a Voltage across a 75 ohm resistor how to get
a power reading. What happens when you switch the unit to
By
lamontcranston17
·
#86253
·
|
Re: Just purchased HP 3586B--EBAY
Hi George, I don't know. I'll receive the unit this week, I'll see if I bought trouble or if I got a deal.
Qmavam
By
lamontcranston17
·
#86252
·
|
Re: Plan to deep cleaning my gear
I keep hearing folks here mentioning water penetration
of circuit board substrates, I think I can help you lay
that myth firmly to rest. The process of making pcb's
has always involved many long
By
Chuck Harris
·
#86251
·
|
Re: HP items for sale
Hello,
sorry for being a bit slow to respond here. The Fluke313 Sounds interesting - would you be willing to ship it inside the USA to a freight forwarder?
---
With best regards
Tam HANNA (emailing on
By
Tam Hanna
·
#86250
·
|
Re: Plan to deep cleaning my gear
I had to remove BI/Beckman trimpots from our products at somewhere around 2000 because they would fail after the boards were cleaned. We switched to Bourns, and the problem went away. BI denied that
By
Michael A. Terrell
·
#86249
·
|
Re: Plan to deep cleaning my gear
I agree with this. I have been involved in many product developments over
40 years ( not for HP) and would not use anything but >99% IPA or DI water,
and only if the parts are rated to be cleaned with
By
Mark Goldberg
·
#86248
·
|
Re: Plan to deep cleaning my gear
I understand the desire to try and get the insides to look like new! Like Paul, I guess I have 50+ bits of oldish HP and Tek equipment, but I'm not sure I would do what you intend, especially with
By
Adrian Nicol <fenland787a@...>
·
#86247
·
|