CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: 8920B Saving last condition?
I'm guessing your running this thing in native mode but if you had it hooked up to the GPIB , then a simple routine could be written to set the new defaults on start-up. Actually thinking about your
By
Artekmedia <manuals@...>
·
#50789
·
|
Re: 8920B Saving last condition?
I don't know about this instrument, but on my 8720D VNA, if a calibration state is saved with the name "UPRESET" then it will power up with that setup. It's a long shot, but you could try naming the
By
David Kirkby <david.kirkby@...>
·
#50788
·
|
Re: 8920B Saving last condition?
My 8920B allows you to save a number of setups. You can use the limited naming capability to ID the frequency it is setup for. As an example, 443500 is my UHF repeater test setup. That's about the
By
Tom Holmes
·
#50787
·
|
Re: 85685A special cabling changes
The Spec An / Preselector combination does not work without the HSWP connection. There is an error that announces the lack of the connection and the instrument will not go beyond that point. As far as
By
billyatams
·
#50786
·
|
Re: counter
Hi Max, I have refurbished many of the 5335A, and several 5334A/B models over the past several years. There is good news and bad news on how repairable these models may be. The bad news is that these
By
Joe Cline
·
#50785
·
|
85685A special cabling changes
I was reading through the online manuals for the 85685A pre-selector, and noticed that they show two different cabling setups in? two different manuals. I was wondering if they are interchangeable or
By
Tim Hughes <timhughes@...>
·
#50784
·
|
Re: counter
If one gets one of these and it doesn't work, how repairable is it? Regards. Max. K 4 O DS. Email: max@... Transistor site http://www.funwithtransistors.net Vacuum tube site:
By
MAX
·
#50783
·
|
8920B Saving last condition?
Hi, Is there a fairly simple keyboard command that will set up the 8920B to 'hold' the last instrument settings for recall when the unit is next powered up? It's time consuming to program 'typical'
By
k8kwh
·
#50782
·
|
Re: counter
The 5334 and 5335 also have reciprocal counting, so keep an eye out for all of them. Last 5334B I got I paid $40 and it was mint. It didn't have the good timebase oscillator but I use a rubidium
By
Peter Gottlieb <hpnpilot@...>
·
#50781
·
|
3709 vs 8981 monitors?
Hi there. Can someone explain to me the difference between what these two instruments are used for? They seem very similar. 3709a/b - Constellation Analyzer 8980/81/a/b - Vector Analyzer and HP 8981A
By
W2HX
·
#50780
·
|
Re: counter
Congratulations, Gene. Now you need to join the EIP_microwave Yahoo Group! -John ==============
By
J. Forster <jfor@...>
·
#50779
·
|
Re: counter
I just bought an EIP 575B which will do 20 GHz with 1 Hz resolution. It also has a source locking feature to steer an oscillator to phase lock it (like a sweeper). Picked it up for $200 on ebay last
By
W2HX
·
#50778
·
|
Re: HP 11664 detector cable
Hi Philippe, ? I believe I have some of these. I will check and let you know. ? Regards, ? Jim
By
Jim Reese
·
#50777
·
|
HP 11664 detector cable
I am looking an extended cable for my 11664 detector. Ineed to make somme measure 5 to 6 meters from my 8757A scalar anlyzer. If somebody have this cable i am interesting. Best regards. Philippe
By
philgievres
·
#50776
·
|
Re: counter
Paul, if you want to measure low frequencies with high resolution, you will definitely want a counter with reciprocal counting. Otherwise you're waiting for ages, especially with audio signals. The
By
adrian_microwave
·
#50775
·
|
Re: New USB to GPIB Board - Galvant Industries - Anyone tried this?
Isn't it casagrande's project with a new name http://www.eevblog.com/forum/buysellwanted/for-sale-oshw-gpibusb-adapter/ https://github.com/Galvant I haven't tried it /Bingo
By
bingo0600
·
#50774
·
|
Part needed
Anyone have a junker HP 3435A? I need the banana jack cap for the current input. This is the screw in cap that carries the fuse. It's common to other meters of the same vintage. A source for the whole
By
k0idt <K0IDT@...>
·
#50773
·
|
Re: counter
Assuming you mean 10 Megahertz, I would recommend the HP5381A. Very simple and small, it has a trim pot for calibration, plus provisions for an external frequency reference input. I have seen many
By
Fred Spaulding <k1yqp@...>
·
#50772
·
|
Re: ho 8558B
I bought a Marconi signal generator for part or repair (I hope the latter when I get around to it) from Israel. The packaging was excellent, postage quite reasonable and it arrived speedily without
By
Jaanette Black
·
#50771
·
|
Re: counter
Might want to take a look at the HP 5315A and B and the 5316A and B. I like the 5334B as well. Might want to download the manuals from the HP website (Agilent) and look at the various options and
By
J. L. Trantham
·
#50770
·
|