¿ªÔÆÌåÓý

Date
Re: 8920B Saving last condition?
I'm guessing your running this thing in native mode but if you had it hooked up to the GPIB , then a simple routine could be written to set the new defaults on start-up. Actually thinking about your
By Artekmedia <manuals@...> · #50789 ·
Re: 8920B Saving last condition?
I don't know about this instrument, but on my 8720D VNA, if a calibration state is saved with the name "UPRESET" then it will power up with that setup. It's a long shot, but you could try naming the
By David Kirkby <david.kirkby@...> · #50788 ·
Re: 8920B Saving last condition?
My 8920B allows you to save a number of setups. You can use the limited naming capability to ID the frequency it is setup for. As an example, 443500 is my UHF repeater test setup. That's about the
By Tom Holmes · #50787 ·
Re: 85685A special cabling changes
The Spec An / Preselector combination does not work without the HSWP connection. There is an error that announces the lack of the connection and the instrument will not go beyond that point. As far as
By billyatams · #50786 ·
Re: counter
Hi Max, I have refurbished many of the 5335A, and several 5334A/B models over the past several years. There is good news and bad news on how repairable these models may be. The bad news is that these
By Joe Cline · #50785 ·
85685A special cabling changes
I was reading through the online manuals for the 85685A pre-selector, and noticed that they show two different cabling setups in? two different manuals. I was wondering if they are interchangeable or
By Tim Hughes <timhughes@...> · #50784 ·
Re: counter
If one gets one of these and it doesn't work, how repairable is it? Regards. Max. K 4 O DS. Email: max@... Transistor site http://www.funwithtransistors.net Vacuum tube site:
By MAX · #50783 ·
8920B Saving last condition?
Hi, Is there a fairly simple keyboard command that will set up the 8920B to 'hold' the last instrument settings for recall when the unit is next powered up? It's time consuming to program 'typical'
By k8kwh · #50782 ·
Re: counter
The 5334 and 5335 also have reciprocal counting, so keep an eye out for all of them. Last 5334B I got I paid $40 and it was mint. It didn't have the good timebase oscillator but I use a rubidium
By Peter Gottlieb <hpnpilot@...> · #50781 ·
3709 vs 8981 monitors?
Hi there. Can someone explain to me the difference between what these two instruments are used for? They seem very similar. 3709a/b - Constellation Analyzer 8980/81/a/b - Vector Analyzer and HP 8981A
By W2HX · #50780 ·
Re: counter
Congratulations, Gene. Now you need to join the EIP_microwave Yahoo Group! -John ==============
By J. Forster <jfor@...> · #50779 ·
Re: counter
I just bought an EIP 575B which will do 20 GHz with 1 Hz resolution. It also has a source locking feature to steer an oscillator to phase lock it (like a sweeper). Picked it up for $200 on ebay last
By W2HX · #50778 ·
Re: HP 11664 detector cable
Hi Philippe, ? I believe I have some of these. I will check and let you know. ? Regards, ? Jim
By Jim Reese · #50777 ·
HP 11664 detector cable
I am looking an extended cable for my 11664 detector. Ineed to make somme measure 5 to 6 meters from my 8757A scalar anlyzer. If somebody have this cable i am interesting. Best regards. Philippe
By philgievres · #50776 ·
Re: counter
Paul, if you want to measure low frequencies with high resolution, you will definitely want a counter with reciprocal counting. Otherwise you're waiting for ages, especially with audio signals. The
By adrian_microwave · #50775 ·
Re: New USB to GPIB Board - Galvant Industries - Anyone tried this?
Isn't it casagrande's project with a new name http://www.eevblog.com/forum/buysellwanted/for-sale-oshw-gpibusb-adapter/ https://github.com/Galvant I haven't tried it /Bingo
By bingo0600 · #50774 ·
Part needed
Anyone have a junker HP 3435A? I need the banana jack cap for the current input. This is the screw in cap that carries the fuse. It's common to other meters of the same vintage. A source for the whole
By k0idt <K0IDT@...> · #50773 ·
Re: counter
Assuming you mean 10 Megahertz, I would recommend the HP5381A. Very simple and small, it has a trim pot for calibration, plus provisions for an external frequency reference input. I have seen many
By Fred Spaulding <k1yqp@...> · #50772 ·
Re: ho 8558B
I bought a Marconi signal generator for part or repair (I hope the latter when I get around to it) from Israel. The packaging was excellent, postage quite reasonable and it arrived speedily without
By Jaanette Black · #50771 ·
Re: counter
Might want to take a look at the HP 5315A and B and the 5316A and B. I like the 5334B as well. Might want to download the manuals from the HP website (Agilent) and look at the various options and
By J. L. Trantham · #50770 ·