CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 Ω) 350C
- Attenuator set (600 Ω) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: How to test a mixer on a hp 8559 plugin in a 853 main frame
When its tuned to freq 000 there's no response
By
steven
·
#49237
·
|
Re: "Event logging" T & M equipment?
Dave,
I'm not sure how big your budget is, but I've picked up good working older model Dranetz power line analyzers for less than $200 on eBay. There are over 250 listings from them up now. They
By
David Speck
·
#49236
·
|
"Event logging" T & M equipment?
Data logging devices are commonplace now days. Many high-end multimeters have such a feature where you can plug the meter up to a power source and record levels over time.
But I'm interested in
By
Dave C <davec2468@...>
·
#49235
·
|
Re: How to test a mixer on a hp 8559 plugin in a 853 main frame
Do you still get zero MHz response? If so, the 1st IF on are working to at least some degree. Baseline noise on wide RBW means the last IF and video are working. Can you inject some signals into
By
WA2SCL_Jeff
·
#49234
·
|
Re: Spectrum Analyzer
Just curious,
What do you think of the Advantest SA vs HP or Tektronix brands?
Thanks in advance.
Jeff M.
________________________________
To: hp_agilent_equipment@...
Sent: Thu,
By
Jeff Miller <jmelect@...>
·
#49233
·
|
Re: How to test a mixer on a hp 8559 plugin in a 853 main frame
By
steven
·
#49232
·
|
Re: 16500 Logic Analyzer Discussion
On Fri, 18 Jan 2013 12:28:35 -0800, you wrote:
>(Changing the subject from spectrum analyzers to logic analyzers)
>
>On Thu, Jan 17, 2013 at 7:51 PM, Harvey White <madyn@...>
By
Harvey White
·
#49231
·
|
Re: Foam conductor problems
After taking these boards apart many times the results were always the same, either one or more LEDs and one or more buttons were not working. Every time it was a different set of buttons or LEDs.
By
John McClung
·
#49230
·
|
Re: HP 3468 DMM battery change
Did you check the power supply voltages?
Joe
By
J. L. Trantham
·
#49229
·
|
Re: Failing 3585A Spectrum Analyzer
You would be amazed at how much noise can get into
test equipment through the power cord...
Corcom filters are nice things, but they do have their
limits.
-Chuck Harris
gldinnc wrote:
By
Chuck Harris
·
#49228
·
|
Re: How to test a mixer on a hp 8559 plugin in a 853 main frame
It very well may still be present, but it would be down quite a bit from where it should be, maybe 20 db or more down. I have an 8558 that was about 10 db down and suspected the mixer. Turned out it
By
WA2SCL_Jeff
·
#49227
·
|
Re: Failing 3585A Spectrum Analyzer
I traced the source of the spikes to some failing halogen light dimmers. I have replaced them and the problem is all but gone.
Why the noise gets in to the 3585 is a mystery, but who cares.
I am
By
Gordon & Lois Duff
·
#49226
·
|
HP 3570A
Well, the 3570A is not working. The A channel gives amplitude readings that are about 90 dB down from the actual input. The B channel is pretty close in amplitude but the phase is way off. So it
By
MAX
·
#49225
·
|
16500 Logic Analyzer Discussion
(Changing the subject from spectrum analyzers to logic analyzers)
The problem with a 16500B
By
Glen Slick
·
#49224
·
|
Re: HP 3468 DMM battery change
Yeah, I disconnected the battery overnight and shorted the RAM chip Vcc to gnd to clear any leftover capcitance, etc. That had no effect. I'm kind of thinking maybe something was on the verge of
By
xyloeye
·
#49223
·
|
How to test a mixer on a hp 8559 plugin in a 853 main frame
If the mixer is bad will there still be a 35mhz calibraed signal on the screen? please let me know asap. thank you
By
steven
·
#49222
·
|
Re: HP-8591E Sweep Modes
Thanks, John ... worked great!
Jeff
By
W8KZW
·
#49221
·
|
Re: Agilent Power Supply
Not exactly their Spanish site but a totally different company. Prologix.com appears to be a logistics company in El Salavador.
The maker of the GPIB USB adapters is a small operation that did not
By
victor.silva
·
#49220
·
|
Re: Hello, and 16500A memory sizes
The DRAM chips only need one more address line to be 4Mbit rather than 1Mbit (they're a matrix, not a linear array), and that address line (pin 5) is definitely wired up (to one of the PALs, if I
By
cmjones01
·
#49219
·
|
Re: Hello, and 16500A memory sizes
Chris, probably you're missing two addressing lines to upgrade it to 4mb. I think i have a newer board with
More memory, but it is some 600km away, i'll take a look at it as soon as i can
Enviado
By
Alexandre Souza
·