CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Added photo album Microscope
#photo-notice
Radu Bogdan Dicher <vondicher@...> added the photo album Microscope ( /g/HP-Agilent-Keysight-equipment/album?id=301362 )
By
Group Notification <noreply@...>
·
#150944
·
|
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
To assist with feedback on this local offer for the Nikon microscopes, I
uploaded to the photos section pictures of the two units this local seller
has:
By
Radu Bogdan Dicher
·
#150943
·
|
Re: HP 8673D synthesized generator - need help identifying the two PC boards attached to A1A11 power amplifier
What a beast. I¡¯ll have to find one as a project.
Peter
By
Peter Gottlieb
·
#150942
·
|
Re: where to find HP 8511A,B and Antenna Measurement System Performance,Verification Software.
I will, IF.
By
John Griessen
·
#150941
·
|
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
And that, my dear sir, is exactly why I wrote the program.
Please contact me off? list.? I didn't exactly design some of this for public consumption (mostly the Embarcadaro stuff), and you'll need
By
Harvey White
·
#150940
·
|
HP 8673D synthesized generator - need help identifying the two PC boards attached to A1A11 power amplifier
I'm on (the other) HP 8673D repair project now. This one never worked in the time I have owned it, and I'd been storing it as a parts mule, but decided (now that I have some experience with
By
David Feldman
·
#150939
·
|
Re: where to find HP 8511A,B and Antenna Measurement System Performance,Verification Software.
Hi John,
I uploaded the "Installation and Getting Started Guide" to the files
area. I don't have the software. I was looking for it a few years ago
but without any luck. I think it was delivered on a
By
Razvan Popescu
·
#150938
·
|
Re: Threads for screws on 8656 Siggen
M3.5 is a standard size 3.5x0.6? the odd one is 3.5x0.5 and yes it exists I have a die for it and the 0.6 ( i use the 0.5 in music instrument repair-silly saxophones).....0.7 never existed nor should
By
Ren¨¦e
·
#150937
·
|
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
Don't grab it, just try it some and see how wide the eyepiece viewing angle is...
When it's narrow you get neck strain quickly keeping your eyes just perfectly located.
By
John Griessen
·
#150936
·
|
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
Fine except for trinocular head is good to have.
By
John Griessen
·
#150935
·
|
where to find HP 8511A,B and Antenna Measurement System Performance,Verification Software.
I might be able to get an HP 8511A...
By
John Griessen
·
#150934
·
|
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
This is not true for all trinocular microscopes, it depends on the model. On mine, both the eyepieces and the camera port are always active at the same time. AmScope calls it "Simul-Focal". I believe
By
squires@...
·
#150933
·
|
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
I use C++ a lot, usually with QtCreator, though I have previously used
Visual Studio. I have Eagle 7.5, 7.6, and 7.7. I use SCAD for 3D
printing and also for general 3D modeling. Your program seems
By
David McQuate
·
#150932
·
|
Re: Threads for screws on 8656 Siggen
OFFICIAL
Thanks for that info.
M3.5 seems to be as rare in Australia as 6-32. I used to have boxes of 4BA stuff, but they have long disappeared in about 10 house moves Ove the last 30 od dyears.
I
By
Wayne Eckert
·
#150931
·
|
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
Any input on the Nikon microscope (SMZ645) I may be able to grab locally?
Radu.
[email protected]> wrote:
By
Radu Bogdan Dicher
·
#150930
·
|
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
I wrote a C++ program that disassembles the .brd file for a project.? It creates an OpenSCAD document that places models of the parts onto the board, giving you a board visualization.? It can handle
By
Harvey White
·
#150929
·
|
Re: Threads for screws on 8656 Siggen
A #6 screw is almost exactly 3.5 mm diameter.
0.6 pitch comes out to just over 42 per inch.
0.7 pitch comes out to just over 36 per inch, but M3.5 x 0.7 does not appear to be a real option.
--
Jim
By
Jim Adney
·
#150928
·
|
Re: Threads for screws on 8656 Siggen
I just noticed that gauge I linked to is 60 degree metric, and 55 degree
imperial (whitworth), so that's not a good "covers both common systems"
thread gauge - that said, I did run into stupid
By
Andrew Hakman
·
#150927
·
|
Re: Threads for screws on 8656 Siggen
I have the screw from an HP8664A, which I assume will be similar. Pan head,
torx drive.
I checked it with various thread gauges, and if you're not looking closely
(i.e. under a magnifier or
By
Andrew Hakman
·
#150926
·
|
Re: hp8970a recallibration attenuator help
Hello Steve yes and an alternative solution here too says so
https://www.simonsdialogs.com/2015/05/hp-agilent-keysight-8970a-noise-figure-meter-getting-started-error-e26/
--
Roberto
By
Roberto
·
#150925
·
|