开云体育

ctrl + shift + ? for shortcuts
© 2025 开云体育
Re: 3" disks for 8566A/B, 8568A/B on HP 9000 Series 200 Computers - Any interest in images?
Tried the Github version v2.0.0 as suggested. It could not read any of the disks Tried Keysights LIFUtils. It could not even format a 3" floppy to LIF using XP or W10. (Both O/S could read and format
By Ulf Kylenfall · #150857 ·
Keysight 23522a Binary Arb Files
Hello Community, I got a 33522a Arb Signal Generator. I'm still looking for a file format description of the binary arb file format ( *.barb ). I found some information about this format and I still
By TomS · #150856 ·
Re: HP 4192A Sweep Utility / Michael Kelzenberg
I uploaded a backup of the help webpage as well as the "full" installer with dependencies. ?When I installed this last November, I had trouble with the light version but the full worked. ?It is
By pac1085 · #150855 ·
File /All HP, Agilent and Keysight instruments in folders by part numbers/4000 to 4999/4192A LF Impedance Analyzer (5 Hz - 13 MHz)/Sweep utilities written by Michael Kelzenberg/Install-4192A-V1-light.exe uploaded #file-notice
The following items have been added to the Files area of the [email protected] group. * /All HP, Agilent and Keysight instruments in folders by part numbers/4000 to 4999/4192A
By Group Notification <noreply@...> · #150854 ·
Re: HP 4192A Sweep Utility / Michael Kelzenberg
[email protected]> wrote: Could you please upload a copy to this directory which I created for the purpose. Place any information you found - a copy of the webpage would
By Dr. David Kirkby, Kirkby Microwave Ltd · #150853 ·
Re: HP 4192A Sweep Utility / Michael Kelzenberg
[email protected]> wrote: Could you please upload a copy to this directory which I created for the purpose. Place any information you found - a copy of the webpage would
By Dr. David Kirkby, Kirkby Microwave Ltd · #150852 ·
Re: HP 4192A Sweep Utility / Michael Kelzenberg
Hi, I have the installer "Install-4192A-V1-light.exe," which means that the NI libraries, for example, are not included. If you would like this program, I can send you a OneDrive link.
By Yves Tardif · #150851 ·
Re: HP 8673D synthesized generator - need replace RF out connector - partial front panel removal suggestions
Thank you, Yves, about working on lower section. I now wish I had made photographs of top-of-bottom, and bottom-of-top areas. There is a panel separating the two sections, with ~8cm x ~15cm opening
By David Feldman · #150850 ·
Re: HP 4192A Sweep Utility / Michael Kelzenberg
I found it. ?Looks like it was a Caltech website that went offline. ?Here is a link to Internet archive backup of it: software.html (
By pac1085 · #150849 ·
Re: HP 3403C True RMS Voltmeter display fault
Hey everyone, Just to inform everyone that the 3403C is back together and running happily. I let it warm up for 3 hours, set up the power supply and used my Adret 104A to setup the DC part. I had to
By AArnaud · #150848 ·
HP 4192A Sweep Utility / Michael Kelzenberg
Hi, Does anyone know what happened to the website for the HP 4192a sweep utility written by Michael Kelzenberg? ?I didn't have it bookmarked so don't recall the URL, I think it was on a university
By pac1085 · #150847 ·
Re: Artek manuals
I bought one in early december and got it back within 2 hrs [email protected]> wrote:
By Paul Carrington · #150846 ·
Re: Artek manuals
An unfortunate choice of words. The owner of Artek (and member of this list) sadly passed away fairly recently but yes, his wife is still running things and I've had several manuals from them in the
By Adrian Nicol · #150845 ·
Re: Artek manuals
Check that the responses aren't being filtered as spam, especially if you use GMail since it seems to change it's internal filtering criteria frequently and without notice. This happened a year or so
By Harold Foster · #150844 ·
Re: Artek manuals
"Warren" <warrens@...> writes: I just bought a Manual yesterday and the download link arrived around one hour later. But i did the automatic paypal checkout, so no manual communication
By Sven Schnelle · #150843 ·
Re: HP 8673D synthesized generator - need replace RF out connector - partial front panel removal suggestions
Hi, Glad to hear you were able to successfully replace the connector. I kept your notes for disassembly; I'll probably have to replace my connector as well. Where did you find the
By Yves Tardif · #150842 ·
Re: 3586A Error 3.1 repaired..thanks to Didier
Hi all, The HEWLETT PACKARD JOURNAL, ?May, 1980 Vol 31 can be downloaded from the hp archive, it's about 30Mb. There is also an article about the companion 3336? signal
By Warren · #150841 ·
Artek manuals
Hello, Is Artek manuals still alive? I've sent two requests for manuals by email, one in February and another in March and have yet to receive a reply (or a failure to deliver notification) to
By Warren · #150840 ·
Re: I need a new/used lab computer
Jim- sorry this was in my drafts file I thought it was sent...dang anyway....I WILL be in the Bay area 15/16 March! I know one is a Win 7 machine, the other I think is an XP. I will send pictures if
By Renée · #150839 ·
Re: 34401A issue
This does seem to be a problem, I have seen quite a lot go over time.. It must be the composition of the plastic... I guess 3D print is the way forward as most other mouldings might suffer from the
By nigel adams · #150838 ·