¿ªÔÆÌåÓý

Date
Re: Wanted: Manual for HP 6116A power supply
Well, how about that. Something must have been up with my internet, as the manual didn't show up on the Artek site when I checked before... I am a happy repeat customer, so that might be the easiest,
By Jared Cabot · #148893 ·
Re: Shielded probe cables?
Yes, the connector on the chassis I believe is FCN-215Q060-G/0 (male).? And for completeness, the connector on the cable side is FCN-214J060-G/0 (female). There are a couple of different flavors,
By Mark Litwack · #148892 ·
Re: HP141T with multiple sections
Removing the CRT won't make much difference to the weight, most of the weight is in the transformer & plug-ins. Also you will still need most of the electronics for the plug-ins. Personally I would
By factory · #148891 ·
Re: Wanted: Manual for HP 6116A power supply
I second, third and fourth that. Not only are the manuals excellent, but Artek is a good firm. ------------------------ Dave (Nick) Daniel KC0WJN ------------------------ [email protected]> wrote:
By Dave Daniel · #148890 ·
Re: Wanted: Manual for HP 6116A power supply
I highly recommend Artek - excellent quality, actual page size (no schematic tiled partial scans), bookmarked - everything is top notch. I personally have an 11x17 color printer home and a binding
By Radu Bogdan Dicher · #148889 ·
Re: Wanted: Manual for HP 6116A power supply
There are three on ePay, one of which might be a copy, one has no picture and this one which is an original (has make offer), maybe someone can help with international shipping, if the seller can't;
By factory · #148888 ·
Re: Wanted: Manual for HP 6116A power supply
That link is for a 6112A (0-40V), not a 6116A ( 0-100 0-100 V). [email protected]> wrote:
By Michael A. Terrell · #148887 ·
Re: Wanted: Manual for HP 6116A power supply
Artek manuals have it - their scans are usually top notch - no connection just a happy customer, I have bought many dozens over the years. http://artekmanuals.com/manuals/hp-manuals/
By Adrian Nicol · #148886 ·
Re: Wanted: Manual for HP 6116A power supply
Have you searched for "HP STB Series Power Supply manual". https://www.manualslib.com/manual/3536743/Hp-Stb-Series.html#manual This link appears to be a better copy than Keysight.
By Tom Haynes · #148885 ·
Re: Wanted: Manual for HP 6116A power supply
Thanks for the link, but this is the same terrible copy as on the Keysight website.
By Jared Cabot · #148884 ·
Re: Wanted: Manual for HP 6116A power supply
https://www.dropbox.com/scl/fi/wnxncyhd8o3bjiglwk9om/hp-6116a-man.pdf?rlkey=bmle7q5xs6zl4xzr1wk2sv2ap&dl=0 [email protected]> wrote:
By Michael A. Terrell · #148883 ·
Re: Shielded probe cables?
You mean on the actual HP/Agilent/Keysight unit? Thanks for all the pointers. I will check them out!
By Anders · #148882 ·
Wanted: Manual for HP 6116A power supply
Hi all, I'm looking for a service manual for a HP 6116A power supply. Either an original paper version, or a high quality scan would be great. (I'll pay for the original paper manual, shipped to
By Jared Cabot · #148881 ·
Re: Shielded probe cables?
[email protected]> wrote: Cables with U.FL connectors are readily available. They use a very thin coax.
By Dr. David Kirkby, Kirkby Microwave Ltd · #148880 ·
Re: Troubleshooting a 8591e with opt 130
Marco, LOG/LIN measurements 300 MHz and 1500 MHz, 0dB to 60dB attenuators are normal, obviously with a 50 or 60dB attenuator, at 1500 MHz, the signal will be noisy. ResBW test are normal too. Flatness
By Yves Tardif · #148879 ·
Re: Shielded probe cables?
Yes, the 54620-61601 is one option. ?It has an easy-to-deal-with 0.1" 2x20 header connector on the chassis side, but can be a bit pricey because it is used on current Keysight products. ?You will
By Mark Litwack · #148878 ·
Re: HP 8566B issue above 18.5GHz ?
At these frequencies it¡¯s always a bit iffy to stack up coax adapters like that, but you would normally see a gradual ¡®suckout¡¯ rather than an abrupt loss of continuity in the sweep if that were
By John Miles · #148877 ·
Re: HP 8566B issue above 18.5GHz ?
There is a specific calibration step for lining up frequencies in different bands. On this analyzer it seems to be off. Ozan
By Ozan · #148876 ·
Re: HP 8566B issue above 18.5GHz ?
I am going back to the manual as there is something weird at 18.6GHz. This a CW signal at the frequency on my 8566B
By Jack · #148875 ·
Re: Troubleshooting a 8591e with opt 130
hi Marco, with the help of Yves, (and of the nice TinySA Ultra) I recently got my 8595E up and running again, after it had been sitting idle for a years, waiting to replace the YTO and the Switched
By alfa beta · #148874 ·