CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: GPIB scripting software?
Yes. If the instrument you are using does SCPI, then it's not to hard to write some code in Python to do some basic measurements. AFAIK, if you have the working GPIB hardware. Keysight 82357B USB/GPIB
By
Roy Thistle
·
#147093
·
|
Re: Artek Manuals and HP 3325B
As I have a couple of EIP 588s in the queue at my bench, I've been looking for the SM out there. Did a quick search, and bam!, one of the free libraries to the rescue!... And as I look closer, in the
By
Radu Bogdan Dicher
·
#147092
·
|
Re: Agilent E4406 fails to turn on - CULPRITS IDENTIFIED
Hi all, Thanks to Milan's pointer I de-soldered the two electrolytic capacitors on the little PSU daughter board and they were faulty. The 47uF@C5 was only 22uF and the 33uF@C6 thinks its a 100ohm
By
Tim Tuck
·
#147091
·
|
Re: Thermal Couple attached to heat sink
John, That pad is thermally conductive and is called a TIM pad. TIM? meansThermal Interface Material. Both Mouser & Digikey among others sell this stuff. Bergquist is one manufacturer but there are
By
2notlit
·
#147090
·
|
Re: 8566B Attenuator Service
Mark - will do. Chuck - these contacts were not gold plated.
By
Jinxie
·
#147089
·
|
Re: 8566B Attenuator Service
Hi Jinxie - Please let us know if the calibration works now. Mark ________________________________ Sent: Monday, September 16, 2024 1:02 PM To: [email protected]
By
Mark Bielman
·
#147088
·
|
Re: 8566B Attenuator Service
If you were working for the telephone company, applying abrasive of any sort to relay contacts would have gotten you fired on the spot. A single technician, helpfully using such a technique could put
By
Chuck Harris
·
#147087
·
|
Re: 8566B Attenuator Service
Thanks, Vladan. Whilst I'd like to do a thorough job on this attenuator, I really need to clear my bench. This whole thing has gone on far too long and I have a backlog of 'stuff' to deal with.
By
Jinxie
·
#147086
·
|
Pb with HP16535A multi probes expansion card for HP16500B logic analyser.
Hi, Yesterday, while using my logic analyser (HP16500B), a component suddenly burned on my HP16535A multi probes expansion card. The PCB is a little damage, but this is fixable. I tested the board and
By
@eikasus
·
#147085
·
|
Re: 8566B Attenuator Service
It's probably residue from a silicone lubricant which was used on attenuators built before mid-1985. The stuff was causing problems so it was eventually abandoned. Unfortunately, a lot of attenuators
By
pianovt
·
#147084
·
|
Re: GPIB scripting software?
I have submitted my e-mail address to Harke Smits. In a project some years ago, I used python routines written by others but never had the time to dive into this language. Looking forward to what I
By
Ulf Kylenfall
·
#147083
·
|
Re: Artek Manuals and HP 3325B
Tim, The Artek office mgr was out due to medical and is back now, filling orders once or twice a week. I'll let them know to expedite if possible. Regards, Ron -
By
Ron
·
#147082
·
|
Twelve(+/-) bins of original HP/Agilent manuals free for pickup in San Diego
I have approximately twelve plastic storage bins (22" x 15" x 12") of test and measurement related manuals that are surplus to my needs. The vast majority of them are HP/Agilent manuals (e.g. scopes,
By
Stan
·
#147081
·
|
Re: Artek Manuals and HP 3325B
The spam filter explanation is extremely likely - I fell prey to that recently. It's been the only issue in years of using their service, other than the unfortunate times when things were in flux due
By
Radu Bogdan Dicher
·
#147080
·
|
Re: Artek Manuals and HP 3325B
No problems at all as late as about 10 days ago.? Pretty sure the email address used will be the same Manuals@... ( manuals@... ) used to contact them so be sure it is not being
By
Harold Foster
·
#147079
·
|
Re: 8566B Attenuator Service
YAY! ________________________________ Sent: Monday, September 16, 2024 9:04 AM To: [email protected] <[email protected]> Subject: Re:
By
Mark Bielman
·
#147078
·
|
Re: Artek Manuals and HP 3325B
That is pretty uncharacteristic for her. At least in my experience.? She has done a great job in keeping up with my manual orders.? I ordered several earlier this year.? I made sure to thank her
By
Frank Mashockie
·
#147077
·
|
Re: Artek Manuals and HP 3325B
Based on my experience what most likely what happened, is she sent the email with the link, and a spam filter somewhere ate it. I contacted her with a different email address a few days after my order
By
Jim n8qoh
·
#147076
·
|
Re: 8566B Attenuator Service
Progress! There was nothing wrong with the logic and the solenoid was *not* energized long-term after all. That 20dB pad was operated by a solenoid which had some kind of contaminant on its lower Y
By
Jinxie
·
#147075
·
|
Re: Artek Manuals and HP 3325B
Dave died, and his widow is trying to keep things running by herself. [email protected]> wrote:
By
Michael A. Terrell
·
#147074
·
|