CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: PAL misconceptions, was Re: [HP-Agilent-Keysight-equipment] 8516A cable question
Agreed 100% about VHDL! -Dave
By
Dave McGuire
·
#122835
·
|
Re: PAL misconceptions, was Re: [HP-Agilent-Keysight-equipment] 8516A cable question
A bit later than Palasm was AHDL from Altera, since bought by Intel.? Kind of nice, as one could generate fairly complex designs quickly and without the overhead BS of VHDL.? VHDL was designed by
By
Jim Ford
·
#122834
·
|
HP 1727A CRO: Problem with the vertical output amplifier.
Hello HP/Agilent/Keysight people! I am? new here, this group was recommended to me by someone on the EEVblog forum, that's where I came from. I have had this HP 1727A scope for a while now and have
By
Alex_03
·
#122833
·
|
Re: Storage Cap Ripple
Hi and thanks for the info. Those tolerances are way tighter than I'd ever imagined! No way can I meet those kind of standards with the meters I have currently. I also very much doubt I have the
By
Jinxie
·
#122832
·
|
Re: HP8568B manual quality
Lou, I have the 8568B manual set from Artek.? It is definitely better!? I can easily read the signal names and pin numbers on that exact area of the schematic. --John Gord
By
John Gord
·
#122831
·
|
Re: HP8568B manual quality
Thanks All, Indeed the quality is excellent and the price is very fair. Example of the same section that I posted before. [image: image.png] Regards Lou VK3ALB wrote:
By
Lou Blasco
·
#122830
·
|
Re: HP 3048A software without floppy disks
It's trivial to edit the source code and comment out that prompt. -Dave -- Dave McGuire, AK4HZ New Kensington, PA
By
Dave McGuire
·
#122829
·
|
Re: HP8568B manual quality
My 8568A manual definitely is much better than your 8568B sample. Raymond
By
Raymond Domp Frank
·
#122828
·
|
Re: HP8568B manual quality
In my experience, Dave's (ArtekManuals') scans are as good as they get. He is dependent on the quality of his original though, which cannot always be a good quality printed version. If you email him
By
Raymond Domp Frank
·
#122827
·
|
Re: PAL misconceptions, was Re: [HP-Agilent-Keysight-equipment] 8516A cable question
That didn't last long, fortunately. I use PALASM today, for when I need PALs/GALs. It's great...simple, fast, no fluff, no BS, predictable. -Dave -- Dave McGuire, AK4HZ New Kensington, PA
By
Dave McGuire
·
#122826
·
|
Re: PAL misconceptions, was Re: [HP-Agilent-Keysight-equipment] 8516A cable question
I remember designing with PALs, GALs, and CPLDs back in the 80's.? Great for reducing the number of SSI TTL chips on a board, but they were power-hogs, if I recall correctly. I did the programming
By
Jeff Anderson
·
#122825
·
|
Re: HP8568B manual quality
I print schematics on a D sized plotter. The schematics from Artek manuals are always excellent quality and print clearly without dropouts or fuzzed lines, even when enlarged. Well worth the very
By
Paul Amaranth
·
#122824
·
|
Re: HP8568B manual quality
Thanks George, That's what I was hoping to hear. -- Regards Lou VK3ALB
By
Lou Blasco
·
#122823
·
|
Re: HP8568B manual quality
All of the manuals I¡¯ve purchased from Artek are much better than your example. George
By
Glydeck
·
#122822
·
|
Re: PAL misconceptions, was Re: [HP-Agilent-Keysight-equipment] 8516A cable question
True, a shift register may be all you can get.? Making a counter can be more difficult because you may not have access to the preset lines on the flipflops. I skipped from the 22V10 directly to
By
Harvey White
·
#122821
·
|
Re: PAL misconceptions, was Re: [HP-Agilent-Keysight-equipment] 8516A cable question
The terms are used interchangeably all over the industry, just like the chips. Yup. Which means you know what you're talking about. -Dave -- Dave McGuire, AK4HZ New Kensington, PA
By
Dave McGuire
·
#122820
·
|
Re: PAL misconceptions, was Re: [HP-Agilent-Keysight-equipment] 8516A cable question
16V8 etc were GAL, not PAL, devices. Erasable, and more flexible architecturally than PAL devices. Used them when I did my first hardware design (professionally I mean). Shows my age I suppose :-/
By
Wilko Bulte
·
#122819
·
|
HP8568B manual quality
Hi, Has anyone purchased HP8568B manuals from Artek and if so are the circuits better image quality than the attached example? [image: image.png] Regards Lou VK3ALB
By
Lou Blasco
·
#122818
·
|
PAL misconceptions, was Re: [HP-Agilent-Keysight-equipment] 8516A cable question
No. The very earliest PALs, like PAL16L8 etc, are combinatorial. But shortly thereafter, 16R8 (etc), the 'R' meaning "Registered", appeared. These are sequential logic devices that store state and
By
Dave McGuire
·
#122817
·
|
Re: 8516A cable question
Points that way. Harvey
By
Harvey White
·
#122816
·
|