CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: FS HP/AGILENT 70205A MMS display
France near Paris
By
jfphp
·
#122577
·
|
Re: FS HP/AGILENT 70205A MMS display
I¡¯m in Northern California, near Sacramento. Mike
By
Michael Perkins
·
#122576
·
|
Re: FS HP/AGILENT 70205A MMS display
Where are you Pete wrote:
By
Pete_G4GJL
·
#122575
·
|
Re: HP 182T display/8559A SA - display only visible with beam find.
with one BNC cable connect the out D BNC on the back to the ext imput BNC on the front (push on EXT) then cek if retrace Sent: Thursday, February 17, 2022 at 3:40 PM From: "Tony" <tonycox01@...>
By
Francesco
·
#122574
·
|
Re: HP8903B - Plotting from HP-IB
Hello everyone, I finally got the HP8903B and it works perfectly. I tried to connect the Prologix interface to the HP-IB connector of the HP8903B and to the PC where I installed some programs for
By
Attilio
·
#122573
·
|
Re: HP 8970B calibration / account for loss during calibration
Are you measuring 50 or 75 ohm devices? If 50 ohm devices, then the pad has to go on the output of the noise source, which affects the ENR of the source¡¯s input to the DUT, and needs to be accounted
By
Tom via Metronet
·
#122572
·
|
Re: HP 182T display/8559A SA - display only visible with beam find.
yes
By
Tony
·
#122571
·
|
HP 8970B calibration / account for loss during calibration
Is it possible to account for a loss between HP8970B and the noise source during calibration? I.e. to have the same loss during calibration and during the measurement. The HP 8970B manual says, that
By
Marc73
·
#122570
·
|
Re: FS HP/AGILENT 70205A MMS display
I¡¯m interested. Did you have a price in mind? Mike [email protected]> wrote:
By
Michael Perkins
·
#122569
·
|
Re: Selling experience, sorry OT again
Dr Dave, Just put a long Dispatch Time in when you list an item. I use 5 Days. (next option is 10) That is the time you hve from the buyer paying and you shipping before it affects your seller
By
Robert G8RPI
·
#122568
·
|
Agilent 86100B recovery operating system software
For sale genuine? recovery operating system software ( envelope, CD, licence and recovery instructions --86100-00036-- ) for Infinium DCA 86100B. MP please.
By
jfphp
·
#122567
·
|
Re: HP 182T display/8559A SA - display only visible with beam find.
Hello Tony, when pushing the button "DISPLAY" get a vertical beam?
By
Francesco
·
#122566
·
|
Re: HP 182T display/8559A SA - display only visible with beam find.
FWIW, I've repaired a good number of 182C and 182T in a distant past and often there was a carbon composition resistor (100 ohms) going open in the cathode drive circuit. Frank
By
Francesco Messineo
·
#122565
·
|
Re: HP 182T display/8559A SA - display only visible with beam find.
Well at least the problem is big and bold. When just beam fid works it will be any of the following. Blanking Z is cutoff for some reason. X or Y or both are totally unbalanced. Typically some sort of
By
paulswed
·
#122564
·
|
Re: HP 182T display/8559A SA - display only visible with beam find.
No, I'm in the UK
By
Tony
·
#122563
·
|
Re: Selling experience, sorry OT again
[quote] I don¡¯t like their new payment system. [/quote] Same here. eBay Managed Payments is a bookeeping nightmare. But payments have been made the day after shipment quite reliably.
By
Precaud
·
#122562
·
|
FS HP/AGILENT 70205A MMS display
For sale small display for the 70K MMS system. Tested OK but the front faceplate and RFI gasket are missing : front plate of the CRT is directly exposed (like the old 180X oscilloscopes), very bright
By
jfphp
·
#122561
·
|
Re: Selling experience, sorry OT again
PayPal fees for FX are incredibly high, 3..5% worst foreign currency exchange rate, plus fees, etc. You always have the option to dump epay all together and simply sell on your own website, our firm
By
Froggie the Gremlin
·
#122560
·
|
Re: HP 182T display/8559A SA - display only visible with beam find.
you hare locate on USA? Sent: Thursday, February 17, 2022 at 7:54 AM From: "Tony" <tonycox01@...> To: [email protected] Subject: Re: [HP-Agilent-Keysight-equipment] HP 182T
By
Francesco
·
#122559
·
|
Re: Selling experience, sorry OT again
Worse than that. Bay charges a higher transaction fee than PayPal. 73 de Brian,VK2GCE Sent: Thursday, 17 February 2022 8:05 PM To: [email protected] Subject: Re:
By
Brian
·
#122558
·
|