CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 ¦¸) 350C
- Attenuator set (600 ¦¸) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: HP8562A Errors 304,335,317,333
I have an 8652b with spurs at -70dBc. In your experience are there any caps which are especially at risk of failure? I have not, yet, opened it to have a look and make measurements. Thanks
By
Tom Gardner
·
#105403
·
|
Re: Problem with HP MMS 70000, USERLOCK ON
1. Are you sure the program did run once or is it the first time you try to run this DLP into this 70900B CPU (coming from an OSA) ? 2. There is no way to test the internal memory 3. Try to erase all
By
jfphp
·
#105402
·
|
Re: Problem with HP MMS 70000, USERLOCK ON
Hi have you looked at the service manual _____ From: [email protected] [mailto:[email protected]] On Behalf Of Pierre-Fran?ois (f5bqp_pfm) Sent: 22 April
By
Paul Bicknell
·
#105401
·
|
Re: Problem with HP MMS 70000, USERLOCK ON
And I measured the effective retention voltage on the vdd of the TC551001CF-70L memories, it's at 2.864v , the datasheet says it should be at 2v minimum to keep up the data, so definitively it's not a
By
Pierre-Fran?ois (f5bqp_pfm)
·
#105400
·
|
Re: Problem with HP MMS 70000, USERLOCK ON
I then decided to open my 70900B, have not done this since many years when I upgraded the firmware with the latest from my previous 70952B. At that time I uploaded this latest firmware on KO4BB web
By
Pierre-Fran?ois (f5bqp_pfm)
·
#105399
·
|
Re: HP8562A Errors 304,335,317,333
Sound advice. Thank you very much. Stu From: [email protected] <[email protected]> On Behalf Of Peter Hansen Sent: 22 April 2020 08:47 To:
By
stur_mm
·
#105398
·
|
Re: HP8562A Errors 304,335,317,333
Hello Stu be very carefull if you will recap the psu. It is an old brittle 4 layer board. solder joints does need alot of heat. You can easy ruin the connection to the middle layer. The 3 legged cap
By
Peter Hansen
·
#105397
·
|
Re: Series 1 & 2 boxes (was Seeking Spring Nuts for Series 1 cabinet)
The System II designation refers to the second design of MODULAR case. Not all HPAK instruments use modular cases. Obviously the ones pre-dating? it? can't. 339A and 3456A both use modular cases,
By
Robert G8RPI
·
#105396
·
|
Re: HP8562A Errors 304,335,317,333
Steve, Waiting for some ¡°Mate N lock¡± plugs to Test an existing board I have funny config but supplies all relevant circuits (RF) associated with errors I¡¯m seeing. Any ideas on the 3 legged
By
stur_mm
·
#105395
·
|
New file uploaded to [email protected]
Hello, This email message is a notification to let you know that the following files have been uploaded to the Files area of the [email protected] group. * /3000 to 3999/HP 3314A
By
[email protected] Notification <HP-Agilent-Keysight-equipment+notification@...>
·
#105394
·
|
Re: Series 1 & 2 boxes (was Seeking Spring Nuts for Series 1 cabinet)
Some photos of System I and System II Cases on my website.HP Cases | | | | HP Cases HP Cases for test equipment System I System II Spare parts for sale ? Azur Electronics HP Cases for test equipment
By
Steve A
·
#105393
·
|
Re: new File called App notes
david.partridge@...> wrote: At least some of it is a result of taking active design steps to hinder counterfeiting. Dave. -- Dr. David Kirkby, Kirkby Microwave Ltd,
By
Dr. David Kirkby, Kirkby Microwave Ltd
·
#105392
·
|
Re: Problem with HP MMS 70000, USERLOCK ON
Hi JF & the Gang, After reloading a fresh DLP NF 70875A from my original ROM personality module I got the same error ERR 2001 and entered once again into the USERLOCK ON dead lock. I was again obliged
By
Pierre-Fran?ois (f5bqp_pfm)
·
#105391
·
|
Re: Decline, was Re: [HP-Agilent-Keysight-equipment] new File called App notes
Lack of understanding of low level hardware is surprisingly common...wrote my latest book because of that. Would, in fact, like to keep this email as a testimonial of sorts... --- With best regards
By
Tam Hanna
·
#105390
·
|
WTB: 5265A Digital Voltmeter for HP 5245L Electronic Counter.
Good Morning, Thought I would ask on the chance that a *5265A Digital Voltmeter* plug-in might be for sale here. I plan to install the 5265A Digital Voltmeter plug-in into a *K37-5245L Converter
By
Terry Gains
·
#105389
·
|
Re: Maximum depth of HP rack mountable gear?
FWIW, here's my experience and method of cutting a rack down to size. Same problem, it was too deep for the available space. http://everist.org/NobLog/20130923_hd_procrastination.htm When setting up
By
Guy Dunphy
·
#105388
·
|
Re: Do ManualsPlus still exist
The loss of ManualsPlus and the other physical archives, was a disaster. Few realize the magnitude. Some links and photos here: http://everist.org/NobLog/20190223_full_spectrum.htm#alex As for
By
Guy Dunphy
·
#105387
·
|
Re: Boonton Type 260-A Q Meter
Regarding the 260, mine had a failure in the constant voltage transformer power supply.? While today's power is much more stable than yesterday's, the system also provides line isolation which is
By
Bob Albert <bob91343@...>
·
#105386
·
|
Re: Boonton Type 260-A Q Meter
Probably the most common problem with the 260 and the RX meter are dirty contacts in the oscillator. Fortunately they are not hard to get to and clean. A few applications of Deoxit will clean them.
By
Richard Knoppow
·
#105385
·
|
Re: HP 3314A manual needed
If possible I¡¯d like a copy, thanks!! S.hanselman@... Regards, Stephen Hanselman Datagate Systems, LLC
By
Stephen Hanselman
·
#105384
·
|