Was thinking of cutting the double banana plug off, and replacing it
with Bnc (with the shunt capacitor also). Was also thinking of putting
BNC on the amp for both probe and another for the output.
By
Daveolla
·
#51
·
|
Re: hp 83522a 2.4 ghz rf plug for 8350b
Thanks for the helpful suggestions, I will check the voltage potential on my DVM.
Regards
Richard Murray
By
RICHARD W. MURRAY
·
#50
·
|
Re: hp 83522a 2.4 ghz rf plug for 8350b
jm
I checked the manual on my protek 506 dvm & it said that the test current for diode testing is 1 ma. The diode in question is acting as a switch which is controlled by a bias voltage based on
By
RICHARD W. MURRAY
·
#48
·
|
Re: hp 83522a 2.4 ghz rf plug for 8350b
Gleamfollower
Any suggestions on how to test a schotsky diode.
Thanks
Richard
By
RICHARD W. MURRAY
·
#44
·
|
Re: hp 83522a 2.4 ghz rf plug for 8350b
I do not think that it is current that would kill schottky diode, it is
reverse voltage that might do it in. Some of very old meters were putting
100 mA on low ohm range, but I do not think that there
By
Miroslav Pokorni
·
#49
·
|
Have HP parts and info, looking for parts...
We have a good cross section of HP parts for test gear, plus an
extensive on line cross reference for HP semiconductors, and a look up
table for many CRTs. you can see this info here:
By
wshawlee2 <walter2@...>
·
#47
·
|
Re: hp 83522a 2.4 ghz rf plug for 8350b
Couple of ways:
1) See how well it acts as a mixer in the frequency range in question.
(This is what I usually test, since the DUT is usually part of a mixer
assembly.)
2) Use a curve tracer with
By
John Miles <jmiles@...>
·
#46
·
|
HP 3469B multimeter
Hi all,
I've got an HP 3469B multimeter that's not behaving as it should - the
display is behaving sensibly, but the values bear little relationship
to the electrical signals applied. Nothing looks
By
higglyblue
·
#45
·
|
New file uploaded to hp_agilent_equipment
Hello,
This email message is a notification to let you know that
a file has been uploaded to the Files area of the hp_agilent_equipment
group.
File : /HP parts Xref.pdf
Uploaded by :
By
hp_agilent_equipment@...
·
#43
·
|
Need knobs for 3580A spectrum analyzer
I have a good-condition HP 3580A spectrum analyzer with many broken
knobs. All four of the span/resolution/sweep knobs to the right of
the CRT are busted, as well as the input attenuator knob. Since
By
dr_charlesmorris <charlesmorris@...>
·
#42
·
|
Service Manuals
Good idea for a group, possibly even overdue!
Sometimes useful service manuals are available here.
http://www.rfsup.com/servicem.html
Richard
By
twobores <rsawday@...>
·
#41
·
|
Re: Difference between 54111D and 54112D
Dave,
Sometimes when I fire up all my equipment, I wish I had a pair of
those hearing protectors that construction workers use.
The whiniest (if such a word) of my equipment is definitely the HP
By
xaos <xaos@...>
·
#40
·
|
Re: Difference between 54111D and 54112D
George
You definitely know the fan is on .....
It is definitely noiser than a tek 7904 , 496 or a 2200 series...
not what I would call objectional per se but far from silent. I think HP in general
By
nr1dx@...
·
#39
·
|
Re: Difference between 54111D and 54112D
Hello Dave,
How about this for a coincidence:
I just purchased the 54111D manual on CD from you at eBay.
I figured I'd look the manuals over before I made a decision.
Thanks for your input. I was
By
xaos <xaos@...>
·
#38
·
|
Re: Difference between 54111D and 54112D
Other things to consider in owning either of theses scopes
I have a love-hate relationship with my (2) 54111D's
On the love side...
1)They are very easy to use, the menus are well thought out and
By
nr1dx@...
·
#37
·
|
Manual for HP 226A Time-Mark Generator
Hi,
First off this is an excellant idea for a group and I wish it much
success, but I guess that really depends on us and how we use it!
I have acquired a HP 226A generator and am looking for a
By
aquaman8_2001
·
#36
·
|
Re: hp 83522a 2.4 ghz rf plug for 8350b
<inertial@j...> wrote:
after
Not usually a good idea to check these diodes with ohmmeters or
(especially) DVM diode-test functions. You may have blown the
diode. :(
By
gleamfollower <jmiles@...>
·
#35
·
|
Difference between 54111D and 54112D
54111D: 500MHz, 2 Ch, 2GS/s max, 8K record length, Color CRT, Auto
measurments, IEEE-488 interface. Out of production '94, out of
support '99.
54112D: 100MHz, 4 ch., 400MS/s digitizing rate, 9"
By
tbfowler100 <tfowler@...>
·
#34
·
|
54111d and 54112D difference
Hello everyone,
I am thinking of buying a scope from eBay, and I was
looking at the 54111D and the 54112D.
Does anyone here know the difference between them?
Cheers,
George Hrysanthopoulos,
By
xaos <xaos@...>
·
#33
·
|
hp 83522a 2.4 ghz rf plug for 8350b
I'm having a problem with the sampler board. I have service manual
but the when I inject a signal in J1 on the board it disappers after
the schotky diode which checks ok on my DVM. Anyone have any
By
RICHARD W. MURRAY
·
#32
·
|