Re: HP 8640b range switch
You can count missing contacts by counting the locations on the rotor where the little plastic posts are broken off. Dave Wise
By Dave Wise · #150806 ·
Re: HP 8640b range switch
Renuad, Those are all great places to start. I have one of these units and I used the technique described on these articles. The epoxy/glue option works very well. I did this on all of the wipe
By G H · #150805 ·
Re: HP 8640b range switch
Hello Mark, Indeed there's a lot on the net about those. Here are some: https://qsl.net/w0mpm/HP8640B.html https://www.qsl.net/ve7ca/TstH86.htm#HK22 https://jvgavila.com/wb1.htm Good luck! Renaud
By Renaud F5ZR · #150804 ·
Re: HP 8640b range switch
There are some good articles on the Internet regarding this problem. Also there is a web site for a company that offers serving of these units, for a price. You ship the entire unit to them and once
By G H · #150803 ·
Re: HP8510C TRL Calibration
Fixed, thanks Jon.
By neil · #150802 ·
Re: hp8921a
Ian, There's a group for the the HP 892XX series it's /g/HP8924-Family-Spectrum-Analyzers/topics ,? Amtronix supports them & provides help their website is
By Bill Higdon · #150801 ·
Re: hp8921a
Thats better, hopefully someone will recognise the issue. Picture is still a bit fuzzy, though I can easily see the two lines at the top of the screen, the second showing the error. The other
By Dave_G0WBX · #150800 ·
HP 8640b range switch
Hi to the group new to this group I have an HP 8640b the frequency range switch has dropped some of its contacts and looking with the times 30 loop on the plastic discs it looks like I'm missing a
By MARK DOTY · #150799 ·
Re: 34401A issue
I saw three and ordered two to have a spare.? Since I have three of this meter and now know about how they can fail I can just replace them as needed.
By Peter Gottlieb · #150798 ·
Re: PARTS IDENTIFICATION
Hi Francesco, just in case this information is still useful to you or anyone else... These assemblies (mixer plus bracket and two resistors) are from a Marconi X17653 Low-Band Receiver unit, part of
By Michael Haben · #150797 ·
Re: 34401A issue
Hi Peter, If I am not mistaken there are 2 Omron relays on the board. If one failed maybe the other one will fail soon so if you make an order and have the unit open it is better to replace
By Razvan Popescu · #150796 ·
Re: 34401A issue
I have tracked this down to K104 and confirmed by bench test the relay has a bad side and won't make continuity to the DC high range attenuator.? With the relay removed I can jumper pins 9 to 13 and
By Peter Gottlieb · #150795 ·
Re: HP 5245L counting/gate problems
The 5300-series counters also have the advantage of portability if the battery pack “plug-on” is added. Jeremy N6WFO [email protected]> wrote:
By Jeremy Nichols · #150794 ·
Re: HP 5245L counting/gate problems
Hi David, Thanks so much for the reply! My “spare” 5245L counter started working so until I get the repair on the current non HP gear fixed so I won’t be tearing into the busted instrument until
By Tom Smith · #150793 ·
Re: hp8921a
By Ian Wells · #150792 ·
Re: 3457A calibration data dump / restore
Hi Jared, Thanks for your inputs. The 3457A doesn't use an NVRAM chip (as other HP instruments do), it uses a low-power CMOS static RAM with a permanent supply provided by a lithium battery. The
By Joel Setton · #150791 ·
Re: hp8921a
Re:-? ".a error does show" What is the exact error message? A photo of the screen would be good. (Cropped and processed to keep the file size sensible.? Saved in a format everyone can see.? .jpg
By Dave_G0WBX · #150790 ·
Re: 3457A calibration data dump / restore
Apparently there are security countermeasures in place to prevent the cal data being written back in via GPIB (Understandable for this sort of equipment, can't have bad actors poking around ruining
By Jared Cabot · #150789 ·
Re: 8656B HPIB connector
Hi Peter, thanks for the advice. I have completed the other repairs? and powered the unit up. amazingly frequency and amplitude appear to be pretty much spot on. Not bad for a unit that hadn't been
By Wayne Eckert · #150788 ·
Re: hp8921a
smps included *12volt rail* 12V 3A 36W *5 volt rail* 5V 6A 30W *43 volt rail* 24V 1A 25W ? Quantity 2 *+ and - 14volt rails* 15V 2A 30W ? Quantity 2
By Ian Wells · #150787 ·