HP 8568B bandpass filter alignment.
Hello, can anyone explain me how can i align the bandpass filters of the HP8568B to have it on SPEC?
My rig passes the self test but the values reported are a little out of spec. Non bad but i would like to have it in the<1db range.
But i don't' know what is the correct procedure to align the instrument.
?
|
Re: 85662A CRT
Hi, Don,
Thanks for replying.? I've got a near perfect one coming from Vladan, but I'm glad to know there are some out there available to the group, as there were others who also had some available, in varying states of life.? If the shipper ruins this one, we'll be in touch. Regards,
Matt
? |
Trigger BOX E5818A
¿ªÔÆÌåÓýHi, ? I have an E5818A, and I'm trying to find the procedure to send a SCPI command via LAN so that the E5818A sends a pulse on the BNC TTL1 or TTL2 port, is anyone familiar with this trigger BOX. |
Re: 85662A CRT
Matt, ??? Where are you located? I have 4 good 85662A CRT,s that have been stored properly for the last 20+ years.? They were pulls from 85662A's that had an arc over issue in the post lead - poor insulation issue. They were factory warranty repairs. I have known good post leads with each one. If interested call me, or email me.? I am in the Chicago, IL, USA metro area. Don Bitters donbitters@... cp 224-406-4059 |
Re: 35665A PSU disassembly
Hi Jeff,
toggle quoted message
Show quoted text
I realize this is a 3 year old post but I found your message while writing the hp wiki entry for the device. The service manual (which I have a paper copy of now) doesn't talk about the power supply in detail. It has 3 or 4 RIFA capacitors and you will want to replace them. To separate the halves you need a set of medical forceps to squeeze a plastic PCB standoff that is used to hold the thing together internally. They were really worried about vibration with this thing. -Evan On Mon, Jul 5, 2021 at 9:19?PM Jeff Keyzer <jeff@...> wrote:
--
-----BEGIN PGP PUBLIC KEY BLOCK----- Version: GnuPG v2 mQENBFYy4RYBCAC183JomLtbdAlcKiaPDoVHq52LDmVmH75aiEc69m7YxDt54/ai VtYCAobbGVIyn3Hlz3uhF6LnPl/6Lm1VdnCfpwu3KQhCO6ds10ow2C30X4ohCqOd hCVg5C+ILmQkEffFrFODy3ji+PYTF4pADvHCWsTMv0hf0llwFOJsBCK6cl02IffE JPqy4PjM1nZ9HpzT84JBaG/4OGvTZ8SQ2yFUl265jagvygPTf88H1xpZHH1r8dB1 stjUHLmPH8AOyDgKxFchgGeDc3p/vJtgDDIXAFfDXG0NSRovLmtaQdGxe47Zf/go bXiEM7YL2WqQe5zfEA919JxkEwlDKYniOSVzABEBAAG0N0V2YW4gRm9zcyAoVGhp cyBpcyBteSBwdWJsaWMga2V5LikgPGV2YW5mb3NzQGdtYWlsLmNvbT6JATkEEwEC ACMFAlYy4RYCGwMHCwkIBwMCAQYVCAIJCgsEFgIDAQIeAQIXgAAKCRCIpQTcE8nN bbBaCACAm8pU5lG1ev2Fsw68Axtcl57SJrYieqX96c3YuYH9JpqMqJRnd9nDKw9X tQuvuH7tUk0VbOaDqReOYJVI/4c5wb9AaOFp6K2DUcupq6XhgXpvz3HzoPwjAdIj XuQzdRUx5+innTJrSkGuBYW/CZ2zqEx4xfLlq4rO0hoTUMR8QVp2cCrkw6BT0m86 APIw/ZnjoxM8IEzr7MxfRIg3qpzrZk28rmhx+k78Jyk61UhwcCPGIm/pjUopTwYJ 3YBdRB2cYD2aN7A1JVf5cRmSQYooHBGpH0kYvomGk97PKqypVuJ7OpG9xM58wUcC qUVt9hKlePLzP8csYjt8onqI7qIIuQENBFYy4RYBCADlH8spG3WkCx62vB5mr5Z0 SCDd/RcyA4A5y5EOj5KurQkrSWpgi9Ho1yKruMJ6blQR2qkc66KqH9pnXDm/ZI1M K/wdW3ngETxBmXoozzFMT89aEWIVR5/PFodWK1elekE9iJxACuR98Zg2QttTD3x8 A9w8VEyMLOXcDTrPFpHegMKswFBg5iuMulAdXAoGejWTI3n+qKFpabHm2Lfs6wjk 5rjucpTdeFK6UeWF1xAvNxXibuu5BlGwv53930qIXRwO/Gn2Rh5DXWxKU2fEIme/ xgQQmIsDeUoWbfybdjw/x7Q0LW4mINiLDQcGHHRQKFIxbAJCT3USPLGh5xwE9/Er ABEBAAGJAR8EGAECAAkFAlYy4RYCGwwACgkQiKUE3BPJzW0uYAf9Hf30n8tM3mR2 Zo6ESE0ivgdgjaJtAWrBUx7JzAzPjBnBOlNnu5Y9lVEqetvUPH6e3PvaHYUuaUU8 0HwxuKBW9nUprgV6uIu1DZmlcp+SxpbuCy7RDpNocRLNWWFMaYYzznmTgfnTgD4D gCq8Mf1mcfrluTkOAo+QNqbMfl1GISClopRqxVuAo59ewgMnFujwgd8w12BwWl24 CzqOs5HqcUslePj+LzcjSNgVCklYwKl+0dsb/fctMOCtHodwqm2CBJ+zydvNmYkD fxda/J91Z1xrah5ec++FL0L4vs+jCiIWJeupJFKlr1hCMZiiGH7W554loK5l4jv3 EY347EidAw== =Ta4p -----END PGP PUBLIC KEY BLOCK----- |
Re: Artek Manuals and HP 3325B
Yes, Artek finally came thru and I was able to repair the unit. ?Root cause of the errors was the 30MHz crystal in the VCO was not oscillating. ?Injecting external signal at the test point restored operation. ?I then removed the crystal and tested it with my 3585A. ?It looked good, so I put it back in and the unit started working. ?I am guessing that the heat of removal caused it to start being a crystal again, weird. ?Either way it has been stable for several weeks now thru multiple power cycles.
--
Tim Wright Senior Engineer Cumulus Media Chicago - WLS-AM AL7DS |
Re: Anyone able to do GC or GC-MS on Hp ThinkJet Black ink ( for the Hp ThinkJet 2225 printer; Hp 9226a Or Hp 51604a ink cartridges ) ?
?
Yup:?
??? Anyone have access to a GC-MS lab that might want to elucidate the ThinkJet ink adventure ?
?
Expected major components in the? Hp 51604A ?Thinkjet black ink cartridge:
? ?( ?3.0mL to 3.7mL ; 0.13 fOz) ? 2-Pyrrolidone Ethelyne Glycol Food Back 2 Acid Salt 3 water ? UFI: 6UE7 - CQTV -A205 - GHXV ? Possibly the MSDS ?(Materials Safety) data sheet ( inserted into product box ), might have additional information ?
?
.... but would be nice to have the GC-MS results,? so that one could make one's own ink, ? as a DIY project !
?
thank you,
rick
?
? |
Re: 8131A Error F500
¿ªÔÆÌåÓý? Hi, ? I have an 8133A, I can imagine how it is built inside the 8131A. ? In the service manual you have the electrical diagrams. The error E304 concerns channel#1, so channel#2 should work fine. By comparing the two channels it would be possible to follow the path and find the faulty section. ? I don't know if you have already attempted this repair, but there is a lot of information in the service manual. ? Yves ? ? ? De?: [email protected] <[email protected]> De la part de vee-dub565 via groups.io ? Well after 6 months on sale on various platforms with no interest. I've now picked up another 8131a, dual output this time hoping to at least make one good one out the two. ? Powered it on annnnd..... E304 error, exactly the same as the one I already have.? ? So now I have two doorstops. No wonder nobody wants them.? |
Re: 8350A RPG 5060-9444 questions
¿ªÔÆÌåÓýHi, This was a fun little project to fix this RPG. The reflector serves as a support for the lamp and also to deflect more light into the tunnels, the amount of light can be controlled by blocking the tunnels towards the photodetectors with two screws. The reflector was just a lightly polished piece of metal, so it was an easily replaceable part if needed. ? When I replaced the lamp with an LED, I didn't need the reflector anymore since the LED covered the tunnel entrances enough. ? I've fixed two of these RPGs, and I've never had a problem since. ? Happy repair. ? Yves De?: [email protected] <[email protected]> De la part de bumbo.chinelo@... ? Thank you Yves Precious feedback yours. The detail of the 45 degree piece of metal is interesting; in both of mine it was missing. Wonder if it is a peculiarity of 8350A or maybe someone else was in there before me and forgot? it.? From your foto now I understand how the lamp is kept in place cheers |
Re: 8350A RPG 5060-9444 questions
Thank you Yves
Precious feedback yours. The detail of the 45 degree piece of metal is interesting; in both of mine it was missing. Wonder if it is a peculiarity of 8350A or maybe someone else was in there before me and forgot? it.? From your foto now I understand how the lamp is kept in place
cheers |
Re: 8131A Error F500
Well after 6 months on sale on various platforms with no interest. I've now picked up another 8131a, dual output this time hoping to at least make one good one out the two.
?
Powered it on annnnd..... E304 error, exactly the same as the one I already have.?
?
So now I have two doorstops. No wonder nobody wants them.? |
8563EC LCD problem
I was given one of these spectrum analysers presumably because the owner didn't think it could or was worth getting fixed. After fixing the power supply, which was a fault caused by two small electrolytics developing a high ESR, the unit powered on and all voltages were as specified.
?
But now I am confronted by a LCD display problem that I can't find a way to progress. Hopefully someone has seen a similar issue and can point me to a solution. Connecting external VGA monitors did not produce any type of display. The best I got was a monitor saying the mode was unsupported.
?
Trying to pull the 8563EC apart to access the LCD itself has proved difficult. I suspect some thread lock glue has been used.
?
? |
Re: Artek Manuals and HP 3325B
Were you able to get the schematic you need for the HP 3325B repair? I
have the paper copy if you need a few pages scanned or something while you wait for the artek copy. On Mon, Sep 16, 2024 at 11:11?AM Tim Wright via groups.io <al7ds@...> wrote:
-- -----BEGIN PGP PUBLIC KEY BLOCK----- Version: GnuPG v2 mQENBFYy4RYBCAC183JomLtbdAlcKiaPDoVHq52LDmVmH75aiEc69m7YxDt54/ai VtYCAobbGVIyn3Hlz3uhF6LnPl/6Lm1VdnCfpwu3KQhCO6ds10ow2C30X4ohCqOd hCVg5C+ILmQkEffFrFODy3ji+PYTF4pADvHCWsTMv0hf0llwFOJsBCK6cl02IffE JPqy4PjM1nZ9HpzT84JBaG/4OGvTZ8SQ2yFUl265jagvygPTf88H1xpZHH1r8dB1 stjUHLmPH8AOyDgKxFchgGeDc3p/vJtgDDIXAFfDXG0NSRovLmtaQdGxe47Zf/go bXiEM7YL2WqQe5zfEA919JxkEwlDKYniOSVzABEBAAG0N0V2YW4gRm9zcyAoVGhp cyBpcyBteSBwdWJsaWMga2V5LikgPGV2YW5mb3NzQGdtYWlsLmNvbT6JATkEEwEC ACMFAlYy4RYCGwMHCwkIBwMCAQYVCAIJCgsEFgIDAQIeAQIXgAAKCRCIpQTcE8nN bbBaCACAm8pU5lG1ev2Fsw68Axtcl57SJrYieqX96c3YuYH9JpqMqJRnd9nDKw9X tQuvuH7tUk0VbOaDqReOYJVI/4c5wb9AaOFp6K2DUcupq6XhgXpvz3HzoPwjAdIj XuQzdRUx5+innTJrSkGuBYW/CZ2zqEx4xfLlq4rO0hoTUMR8QVp2cCrkw6BT0m86 APIw/ZnjoxM8IEzr7MxfRIg3qpzrZk28rmhx+k78Jyk61UhwcCPGIm/pjUopTwYJ 3YBdRB2cYD2aN7A1JVf5cRmSQYooHBGpH0kYvomGk97PKqypVuJ7OpG9xM58wUcC qUVt9hKlePLzP8csYjt8onqI7qIIuQENBFYy4RYBCADlH8spG3WkCx62vB5mr5Z0 SCDd/RcyA4A5y5EOj5KurQkrSWpgi9Ho1yKruMJ6blQR2qkc66KqH9pnXDm/ZI1M K/wdW3ngETxBmXoozzFMT89aEWIVR5/PFodWK1elekE9iJxACuR98Zg2QttTD3x8 A9w8VEyMLOXcDTrPFpHegMKswFBg5iuMulAdXAoGejWTI3n+qKFpabHm2Lfs6wjk 5rjucpTdeFK6UeWF1xAvNxXibuu5BlGwv53930qIXRwO/Gn2Rh5DXWxKU2fEIme/ xgQQmIsDeUoWbfybdjw/x7Q0LW4mINiLDQcGHHRQKFIxbAJCT3USPLGh5xwE9/Er ABEBAAGJAR8EGAECAAkFAlYy4RYCGwwACgkQiKUE3BPJzW0uYAf9Hf30n8tM3mR2 Zo6ESE0ivgdgjaJtAWrBUx7JzAzPjBnBOlNnu5Y9lVEqetvUPH6e3PvaHYUuaUU8 0HwxuKBW9nUprgV6uIu1DZmlcp+SxpbuCy7RDpNocRLNWWFMaYYzznmTgfnTgD4D gCq8Mf1mcfrluTkOAo+QNqbMfl1GISClopRqxVuAo59ewgMnFujwgd8w12BwWl24 CzqOs5HqcUslePj+LzcjSNgVCklYwKl+0dsb/fctMOCtHodwqm2CBJ+zydvNmYkD fxda/J91Z1xrah5ec++FL0L4vs+jCiIWJeupJFKlr1hCMZiiGH7W554loK5l4jv3 EY347EidAw== =Ta4p -----END PGP PUBLIC KEY BLOCK----- |